The DOI matches its Crossref record.
Reflecting time-of-flight mass spectrometer with an electrospray ion source and orthogonal extraction
Abstract
An electrospray source has been coupled to a reflecting time-of-flight mass spectrometer. The ions enter as a continuous beam in a direction perpendicular to the spectrometer axis and are formed into short bursts of ions with velocities parallel to the axis by electrical pulses applied to injection electrodes. The instrument may be operated either in the linear mode, with ions detected behind the electrostatic mirror, or in the reflecting mode, with ions detected after reflection. In the latter case the time resolution is < or = 8 ns for m/z approximately 600, enabling observation of individual isotopic peaks for masses up to about 4000 u. The sensitivity is adequate to enable measurement of mass spectra for 10 fmol of cytochrome c (approximately 12,000 u). The spectrometer does not limit the range of m/z values, and ions have been observed up to m/z approximately 6000. With proper adjustment of pH and other conditions in the source, the ionization is very soft, enabling injection of weakly bound complexes; these have been accelerated and measured in the spectrometer without observable fragmentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular Biologist's Guide to Proteomics
Graves, P. R., & Haystead, T. A. J. (2002) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.66.1.39-63.2002 · Cited by 691
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“On the other hand, time-of-flight (ToF) mass analyzers have no theoretical upper mass range, and can achieve high sensitivity and resolution on a fast timescale [38].”
BackgroundDelayed extraction matrix‐assisted laser desorption time‐of‐flight mass spectrometry
Vestal, M. L., Juhasz, P., & Martin, S. A. (1995) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290091115 · Cited by 497
High-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
Przybylski, M., & Glocker, M. O. (1996) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199608061 · Cited by 351
Orthogonal acceleration time-of-flight mass spectrometry
Guilhaus, M., Selby, D., & Mlynski, V. (2000) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(2000)19:2<65::aid-mas1>3.0.co;2-e · Cited by 338
Mass spectrometry for structural characterization of therapeutic antibodies
Zhang, Z., Pan, H., & Chen, X. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20190 · Cited by 316
Loboda, A. V., Krutchinsky, A. N., Bromirski, M., Ens, W., & Standing, K. G. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000630)14:12<1047::aid-rcm990>3.0.co;2-e · Cited by 305
Self-citationHigh Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Zhao, Y., Riley, N. M., Sun, L., Hebert, A. S., Yan, X., Westphall, M. S., Rush, M. J. P., Zhu, G., Champion, M. M., Medie, F. M., et al. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00883 · Cited by 55
Hepatocyte [3H]-palmitate uptake: effect of albumin surface charge modification
Burczynski, F. J., Wang, G. Q., Elmadhoun, B., She, Y. M., Roberts, M. S., & Standing, K. G. (2001) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y01-072 · Cited by 28
Self-citation
Metadata
- Authors
- Verentchikov, A. N., Ens, W., & Standing, K. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1994-01-01
- Volume
- 66
- Issue
- 1
- Pages
- 126-133
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2055893109
- Cited by
- 223
- References
- 0
- FWCI
- 13.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.