The DOI matches its Crossref record.
Characterization of Glucose Oxidase-Modified Poly(phenylenediamine)-Coated Electrodes in vitro and in vivo: Homogeneous Interference by Ascorbic Acid in Hydrogen Peroxide Detection
Abstract
The response of glucose oxidase (GOx) modified poly(o-phenylenediamine) coated Pt disk electrodes to glucose was well-behaved with a rapid response time and displaying Michaelis-Menten kinetics. However, the glucose response was lowered in a concentration-dependent manner by ascorbic acid when the glucose calibrations were carried out in solutions containing this reducing agent. The possibility of a homogeneous redox reaction in which the H2O2 generated by tie enzymatic oxidation of glucose at the GOx/polymer surface is consumed by ascorbate was investigated. Similar ''negative'' interference at GOx-modified carbon powder electrodes not involving membranes and for H2O2 calibrations at bare Pt electrodes supported the hypothesis. The observation that this interference could be blocked by the chelating agent EDTA suggests that the homogeneous reaction is catalyzed by trace metal ion impurities in solution. A model for the homogeneous reaction based on these experimental findings is proposed and tested by comparing quiescent and stirred solutions. No homogeneous interference by uric acid was observed. The electrodes were found to be free from lipid fouling in vitro, and experiments monitoring brain glucose levels in vivo indicate the absence of the homogeneous reaction in this environment. The results highlight the need to test each individual assay procedure involving H2O2 under relevant conditions for both positive and negative interference by ascorbic acid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cosnier, S. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00024-x · Cited by 768
Novel Multifunctional Polymers from Aromatic Diamines by Oxidative Polymerizations
Li, X.-G., Huang, M.-R., Duan, W., & Yang, Y.-L. (2002) · Chemical Reviews · doi:10.1021/cr010423z · Cited by 682
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Non-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
Metadata
- Authors
- Lowry, J. P., McAteer, K., El Atrash, S. S., Duff, A., & O'Neill, R. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1994-05-15
- Volume
- 66
- Issue
- 10
- Pages
- 1754-1761
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1964975785
- Cited by
- 183
- References
- 0
- FWCI
- 13.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of Glucose Oxidase-Modified Poly(phenylenediamine)-Coated Electrodes in vitro and in vivo: Homogeneous Interference by Ascorbic Acid in Hydrogen Peroxide Detection. https://app.cochat.ai/papers/10.1021/ac00082a025
- The paper
- Lowry, J. P., McAteer, K., El Atrash, S. S., Duff, A., & O'Neill, R. D. (1994). Characterization of Glucose Oxidase-Modified Poly(phenylenediamine)-Coated Electrodes in vitro and in vivo: Homogeneous Interference by Ascorbic Acid in Hydrogen Peroxide Detection. Analytical Chemistry. https://doi.org/10.1021/ac00082a025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.