The DOI matches its Crossref record.
A Picoliter-Volume Mixer for Microfluidic Analytical Systems
Abstract
Mixing confluent liquid streams is an important, but difficult operation in microfluidic systems. This paper reports the construction and characterization of a 100-pL mixer for liquids transported by electroosmotic flow. Mixing was achieved in a microfabricated device with multiple intersecting channels of varying lengths and a bimodal width distribution. All channels running parallel to the direction of flow were 5 microm in width whereas larger 27-microm-width channels ran back and forth through the parallel channel network at a 45 degrees angle. The channel network composing the mixer was approximately 10 microm deep. It was observed that little mixing of the confluent solvent streams occurred in the 100-microm-wide, 300-microm-long mixer inlet channel where mixing would be achieved almost exclusively by diffusion. In contrast, after passage through the channel network in the approximately 200-microm-length static mixer bed, mixing was complete as determined by confocal microscopy and CCD detection. Theoretical simulations were also performed in an attempt to describe the extent of mixing in microfabricated systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Micromixers—a review on passive and active mixing principles
Hessel, V., Löwe, H., & Schönfeld, F. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2004.11.033 · Cited by 1,479
Lee, C.-Y., Chang, C.-L., Wang, Y.-N., & Fu, L.-M. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12053263 · Cited by 1,111
Digital microfluidics: is a true lab-on-a-chip possible?
Fair, R. B. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0161-8 · Cited by 1,063
Hansen, C. L., Skordalakes, E., Berger, J. M., & Quake, S. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.262485199 · Cited by 517
Microchemical systems for continuous-flow synthesis
Hartman, R. L., & Jensen, K. F. (2009) · Lab on a Chip · doi:10.1039/b906343a · Cited by 508
Lab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
Micromixing Within Microfluidic Devices
Capretto, L., Cheng, W., Hill, M., & Zhang, X. (2011) · Topics in Current Chemistry · doi:10.1007/128_2011_150 · Cited by 448
Self-citationEnhancement of microfluidic mixing using time pulsing
Glasgow, I., & Aubry, N. (2003) · Lab Chip · doi:10.1039/b302569a · Cited by 370
Paik, P., Pamula, V. K., Pollack, M. G., & Fair, R. B. (2003) · Lab on a Chip · doi:10.1039/b210825a · Cited by 327
Hosokawa, K., Sato, K., Ichikawa, N., & Maeda, M. (2004) · Lab on a Chip · doi:10.1039/b403930k · Cited by 260
Metadata
- Authors
- He, B., Burke, B. J., Zhang, X., Zhang, R., & Regnier, F. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-03-28
- Volume
- 73
- Issue
- 9
- Pages
- 1942-1947
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2021836285
- Cited by
- 200
- References
- 0
- FWCI
- 12.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.