Separation of Nanoliter Samples of Biological Amines by a Comprehensive Two-Dimensional Microcolumn Liquid Chromatography System
The DOI matches its Crossref record.
Abstract
A two-dimensional liquid chromatography system based on the combination of a charge separation mechanism, provided by anion exchange chromatography, with a hydrophobic separation mechanism, provided by reversed phase chromatography, is presented. A 90 cm long anion exchange microcolumn is coupled to a 3 cm long reversed phase microcolumn. Both microcolumns are interfaced by two electronically controlled valves. Effluent from the anion exchange microcolumn is collected in a sample loop and then concentrated onto the head of the reversed phase microcolumn. Analyte peaks consisting of tagged amines elute from the second column and are detected by laser-induced fluorescence. The entire operation is controlled by a personal computer. The resolving power of this system is demonstrated with a two-dimensional chromatogram of the peptides obtained from a tryptic digest of porcine thyroglobulin. The sensitivity of the system is demonstrated with a two-dimensional chromatogram of the contents of a single bovine chromaffin cell.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
“Other materials used as first dimension (1D) are size exclusion (97), anion-exchange, (105) and a mixed-bed approach (106).”
BackgroundEffect of Sampling Rate on Resolution in Comprehensive Two-Dimensional Liquid Chromatography
Murphy, R. E., Schure, M. R., & Foley, J. P. (1998) · Analytical Chemistry · doi:10.1021/ac971184b · Cited by 436
Jackman, R. J., Duffy, D. C., Ostuni, E., Willmore, N. D., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac971295a · Cited by 304
Comprehensive On-Line LC/LC/MS of Proteins
Opiteck, G. J., Lewis, K. C., Jorgenson, J. W., & Anderegg, R. J. (1997) · Analytical Chemistry · doi:10.1021/ac961155l · Cited by 286
Self-citationTwo-Dimensional SEC/RPLC Coupled to Mass Spectrometry for the Analysis of Peptides
Opiteck, G. J., Jorgenson, J. W., & Anderegg, R. J. (1997) · Analytical Chemistry · doi:10.1021/ac961156d · Cited by 278
Self-citation
Metadata
- Authors
- Holland, L. A., & Jorgenson, J. W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-09-15
- Volume
- 67
- Issue
- 18
- Pages
- 3275-3283
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2022096638
- Cited by
- 128
- References
- 0
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Separation of Nanoliter Samples of Biological Amines by a Comprehensive Two-Dimensional Microcolumn Liquid Chromatography System. https://app.cochat.ai/papers/10.1021/ac00114a026
- The paper
- Holland, L. A., & Jorgenson, J. W. (1995). Separation of Nanoliter Samples of Biological Amines by a Comprehensive Two-Dimensional Microcolumn Liquid Chromatography System. Analytical Chemistry. https://doi.org/10.1021/ac00114a026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.