The DOI matches its Crossref record.
Attomole-Sensitivity Electrospray Source for Large-Molecule Mass Spectrometry
Abstract
Full mass spectra of high resolving power are obtained from 0.2 nL sample volumes of large (> 10 kDa) nucleotides and proteins using a new electrospray ionization (ESI) system combined with Fourier transform mass spectrometry. The ESI needles are fabricated by laser-heated pulling of fused-silica tubing (5-20 microns i.d.), followed by chemical etching and surface metalization. Total analyte loaded at the instrument of 8.6 fmol and 216 amol produces signal-to-noise ratios of 400:1 and 60:1, respectively, and resolving power of > 10(5) for full mass spectra, while the total amount of material consumed is approximately 150 and 10 amol, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Attomole Protein Characterization by Capillary Electrophoresis-Mass Spectrometry
Valaskovic, G. A., Kelleher, N. L., & McLafferty, F. W. (1996) · Science · doi:10.1126/science.273.5279.1199 · Cited by 398
Self-citationMartin, S. E., Shabanowitz, J., Hunt, D. F., & Marto, J. A. (2000) · Analytical Chemistry · doi:10.1021/ac000497v · Cited by 276
Data storage using peptide sequences
Ng, C. C. A., Tam, W. M., Yin, H., Wu, Q., So, P.-K., Wong, M. Y.-M., Lau, F. C. M., & Yao, Z.-P. (2021) · Nature Communications · doi:10.1038/s41467-021-24496-9 · Cited by 41
Metadata
- Authors
- Valaskovic, G. A., Kelleher, N. L., Little, D. P., Aaserud, D. J., & McLafferty, F. W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-10-01
- Volume
- 67
- Issue
- 20
- Pages
- 3802-3805
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2015153974
- Cited by
- 217
- References
- 0
- FWCI
- 10.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.