The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Protein Sizing on a Microchip
Abstract
We have developed a microfabricated analytical device on a glass chip that performs a protein sizing assay, by integrating the required separation, staining, virtual destaining, and detection steps. To obtain a universal noncovalent fluorescent labeling method, we have combined on-chip dye staining with a novel electrophoretic dilution step. Denatured protein-sodium dodecyl sulfate (SDS) complexes are loaded on a chip and bind a fluorescent dye as the separation begins. At the end of the separation channel, an intersection is used to dilute the SDS below its critical micelle concentration before the detection point. This strongly reduces the background due to dye molecules bound to SDS micelles and also increases the peak amplitude by 1 order of magnitude. Both the on-chip staining and SDS dilution steps occur in the 100-ms time scale and are approximately 10(4) times faster than their conventional counterparts in SDS-PAGE. This represents a much greater speed increase due to microfabrication than has been obtained in other assay steps such as electrophoretic separations. We have designed and tested a microchip capable of sequentially analyzing 11 different samples, with sizing accuracy better than 5% and high sensitivity (30 nM for carbonic anhydrase).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4
LAEMMLI, U. K. (1970) · Nature · doi:10.1038/227680a0 · Cited by 249,961
Molecular cloning: A laboratory manual
Deininger, P. (1990) · Analytical Biochemistry · doi:10.1016/0003-2697(90)90595-z · Cited by 84,682
Molecular weight estimation of polypeptide chains by electrophoresis in SDS-polyacrylamide gels
Shapiro, A. L., Viñuela, E., & V. Maizel, J. (1967) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(67)90391-9 · Cited by 3,763
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Woolley, A. T., & Mathies, R. A. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.24.11348 · Cited by 605
High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
Sundberg, S. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00051-8 · Cited by 455
GCN5-Related N-Acetyltransferases: A Structural Overview
Dyda, F., Klein, D. C., & Hickman, A. B. (2000) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.29.1.81 · Cited by 455
Chattopadhyay, A., & London, E. (1984) · Analytical Biochemistry · doi:10.1016/0003-2697(84)90026-5 · Cited by 409
Cohen, A. S., & Karger, B. L. (1987) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)85026-3 · Cited by 378
Tailoring of Sol−Gel Films for Optical Sensing of Oxygen in Gas and Aqueous Phase
McDonagh, C., MacCraith, B. D., & McEvoy, A. K. (1998) · Analytical Chemistry · doi:10.1021/ac970461b · Cited by 266
Chiem, N. H., & Harrison, D. J. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.591 · Cited by 264
Ganzler, K., Greve, K. S., Cohen, A. S., Karger, B. L., Guttman, A., & Cooke, N. C. (1992) · Analytical Chemistry · doi:10.1021/ac00046a003 · Cited by 242
Brito, R. M. M., & Vaz, W. L. C. (1986) · Analytical Biochemistry · doi:10.1016/0003-2697(86)90406-9 · Cited by 224
Characteristics of a Vitamin A-transporting Protein Complex Occurring in Human Serum
Peterson, P. A. (1971) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)62528-1 · Cited by 216
Hunt, G. E., & Nashabeh, W. (1999) · Analytical Chemistry · doi:10.1021/ac981209m · Cited by 154
Pinto, D. M., Arriaga, E. A., Craig, D., Angelova, J., Sharma, N., Ahmadzadeh, H., Dovic̀hi, N. J., & Boulet, C. A. (1997) · Analytical Chemistry · doi:10.1021/ac9611677 · Cited by 130
Widhalm, A., Schwer, C., Blaas, D., et al. (1991) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)91458-4 · Cited by 110
Cited by
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Integrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Grover, W. H., Skelley, A. M., Liu, C. N., Lagally, E. T., & Mathies, R. A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00468-9 · Cited by 517
Disposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Metadata
- Authors
- Bousse, L., Mouradian, S., Minalla, A., Yee, H., Williams, K., & Dubrow, R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-02-08
- Volume
- 73
- Issue
- 6
- Pages
- 1207-1212
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1968960019
- Cited by
- 283
- References
- 18
- FWCI
- 21.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.