The DOI matches its Crossref record.
Cross-linked redox gels containing glucose oxidase for amperometric biosensor applications
Abstract
Oxidoreductases, such as glucose oxidase, can be electrically "wired" to electrodes by electrostatic complexing or by covalent binding of redox polymers so that the electrons flow from the enzyme, through the polymer, to the electrode. We describe two materials for amperometric biosensors based on a cross-linkable poly(vinylpyridine) complex of [Os-(bpy)2Cl]+2+ that communicates electrically with flavin adenine dinucleotide redox centers of enzymes such as glucose oxidase. The uncomplexed pyridines of the poly(vinylpyridine) are quaternized with two types of groups, one promoting hydrophilicity (2-bromoethanol or 3-bromopropionic acid), the other containing an active ester (N-hydroxysuccinimide) that forms amide bonds with both lysines on the enzyme surface and with an added polyamine cross-linking agent (triethylenetetraamine, trien). In the presence of glucose oxidase and trien this polymer forms rugged, cross-linked, electroactive films on the surface of electrodes, thereby eliminating the requirement for a membrane for containing the enzyme and redox couple. The glucose response time of the resulting electrodes is less than 10 s. The glucose response under N2 shows an apparent Michaelis constant, Km' = 7.3 mM, and limiting current densities, jmax, between 100 and 800 microA/cm2. Currents are decreased by 30-50% in air-saturated solutions because of competition between O2 and the Os(III) complex for electrons from the reduced enzyme. Rotating ring desk experiments in air-saturated solutions containing 10 mM glucose show that about 20% of the active enzyme is electrooxidized via the Os(III) complex, while the rest is oxidized by O2. These results suggest that only part of the active enzyme is in electrical contact with the electrode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
Chaubey, A., & Malhotra, B. D. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00313-x · Cited by 777
Enzyme catalysed biofuel cells
Cooney, M. J., Svoboda, V., Lau, C., Martin, G., & Minteer, S. D. (2008) · Energy & Environmental Science · doi:10.1039/b809009b · Cited by 391
Prospects of conducting polymers in biosensors
Malhotra, B. D., Chaubey, A., & Singh, S. P. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.055 · Cited by 372
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Nanomaterials for bio-functionalized electrodes: recent trends
Walcarius, A., Minteer, S. D., Wang, J., Lin, Y., & Merkoçi, A. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20881h · Cited by 366
Electrochemistry in Diabetes Management
Heller, A., & Feldman, B. (2010) · Accounts of Chemical Research · doi:10.1021/ar9002015 · Cited by 255
Self-citation
Metadata
- Authors
- Gregg, B. A., & Heller, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1990-02-01
- Volume
- 62
- Issue
- 3
- Pages
- 258-263
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2029073332
- Cited by
- 479
- References
- 0
- FWCI
- 30.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.