Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 570

The DOI matches its Crossref record.

Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film

Malitesta, Cosimino., Palmisano, Francesco., Torsi, Luisa., Zambonin, Pier Giorgio.·1990·Analytical Chemistry

Abstract

o-Phenylenediamine has been used for glucose oxidase (GOx) immobilization on Pt electrodes by electrochemical polymerization at +0.65 V vs SCE. By this approach the enzyme is entrapped in a strongly adherent, highly reproducible thin membrane, whose thickness is around 10 nm. This one-step procedure produces a glucose sensor with a response time less than 1 s, an active enzyme loading higher than 3 units/cm2 of electrode surface, a high sensitivity, and a sufficiently wide linear range. The glucose response shows an apparent Michaelis-Menten constant, K'm = 14.2 mM, and a limiting current density, jmax of 181 microA/cm2. The product kD of partition and diffusion coefficients of glucose in the polymer film is on the order of 10(-13) cm2/s. Due to permselectivity characteristics of the membrane, the access of ascorbate, a common interfering species, to the electrode surface is blocked. To our knowledge, this represents the first report of a membrane capable, at the same time, of immobilizing GOx and rejecting ascorbate. The interesting electrode behavior can be rationalized by using an existing model predicting the amperometric response of an immobilized GOx system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac00223a016

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 570

Metadata

Authors
Malitesta, C., Palmisano, F., Torsi, L., & Zambonin, P. G.
Venue
Analytical Chemistry
Published
1990-12-15
Volume
62
Issue
24
Pages
2735-2740
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2015139372
Cited by
570
References
0
FWCI
13.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film. https://app.cochat.ai/papers/10.1021/ac00223a016
The paper
Malitesta, C., Palmisano, F., Torsi, L., & Zambonin, P. G. (1990). Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film. Analytical Chemistry. https://doi.org/10.1021/ac00223a016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.