The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Kendrick Mass Defect Spectrum: A Compact Visual Analysis for Ultrahigh-Resolution Broadband Mass Spectra
Abstract
At currently achievable Fourier transform ion cyclotron resonance broadband mass spectrometry resolving power (m/deltam50% > 350,000 for 200 < m/z < 1,000), it would be necessary to spread out a conventional mass spectrum over approximately 200 m in order to provide visual resolution of the most closely resolved peaks. Fortunately, there are natural gaps in a typical mass spectrum, spaced 1 Da apart, because virtually no commonly encountered elemental compositions yield masses at those values. Thus, it is possible to break a broadband mass spectrum into 1-Da segments, rotate each segment by 90 degrees, scale each segment according to its mass defect (i.e., difference between exact and nominal mass), and then compress the spacing between the segments to yield a compact display. For hydrocarbon systems, conversion from IUPAC mass to "Kendrick" mass (i.e., multiplying each mass by 14.00000/14.01565) further simplifies the display by rectilinearizing the peak patterns. The resulting display preserves not only the "coarse" spacings (e.g., approximately 1 Da between odd and even masses, corresponding to either even vs odd number of nitrogens or 12C(c) vs 12C(c-1)13C1 elemental compositions of the same molecule; approximately 2-Da separations, corresponding to a double bond or ring; approximately 14 Da separations, corresponding to one CH2 group) but also the "fine structure" (i.e., different mass defects for different elemental compositions) across each 1-Da segment. The method is illustrated for experimental electrospray ionization FTICR ultrahigh-resolution mass spectra of a petroleum crude oil. Several thousand elemental compositions may be resolved visually in a single one-page two-dimensional display, and various compound families-class (NnOoSs), type (Z in C(c)H2(c+z)NnOoSs), and alkylation series-may be identified visually as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Self-citationThe 1995 update to the atomic mass evaluation
Audi, G., & Wapstra, A. H. (1995) · Nuclear Physics A · doi:10.1016/0375-9474(95)00445-9 · Cited by 1,462
A Mass Scale Based on CH2 = 14.0000 for High Resolution Mass Spectrometry of Organic Compounds.
Kendrick, E. (1963) · Analytical Chemistry · doi:10.1021/ac60206a048 · Cited by 730
Interpretation of mass spectra
(1994) · Choice Reviews Online · doi:10.5860/choice.31-2693 · Cited by 498
Space charge effects in Fourier transform mass spectrometry. II. Mass calibration
Ledford, E. B., Rempel, D. L., & Gross, M. L. (1984) · Analytical Chemistry · doi:10.1021/ac00278a027 · Cited by 468
Senko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 462
Self-citationMilestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
Self-citationEmmett, M. R., White, F. M., Hendrickson, C. L., Shi, S. D. H., & Marshall, A. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00287-0 · Cited by 211
Self-citationMass and abundance tables for use in mass spectrometry
Beynon, J. H., & Williams, A. E. (1963) · Elsevier eBooks · Cited by 123
Cited by
Kim, S., Kramer, R. W., & Hatcher, P. G. (2003) · Analytical Chemistry · doi:10.1021/ac034415p · Cited by 1,336
Petroleomics: The Next Grand Challenge for Chemical Analysis
Marshall, A. G., & Rodgers, R. P. (2004) · Accounts of Chemical Research · doi:10.1021/ar020177t · Cited by 817
Self-citationPetroleomics: Chemistry of the underworld
Marshall, A. G., & Rodgers, R. P. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805069105 · Cited by 673
Self-citationThe Molecular Identification of Organic Compounds in the Atmosphere: State of the Art and Challenges
Nozière, B., Kalberer, M., Claeys, M., Allan, J., D’Anna, B., Decesari, S., Finessi, E., Glasius, M., Grgić, I., Hamilton, J. F., et al. (2015) · Chemical Reviews · doi:10.1021/cr5003485 · Cited by 656
Current approaches and challenges for the metabolite profiling of complex natural extracts
Wolfender, J.-L., Marti, G., Thomas, A., & Bertrand, S. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.091 · Cited by 635
Metadata
- Authors
- Hughey, C. A., Hendrickson, C. L., Rodgers, R. P., Marshall, A. G., & Qian, K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-08-31
- Volume
- 73
- Issue
- 19
- Pages
- 4676-4681
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1963761986
- Cited by
- 851
- References
- 9
- FWCI
- 5.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.