The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Variations in Coupled Water, Viscoelastic Properties, and Film Thickness of a Mefp-1 Protein Film during Adsorption and Cross-Linking: A Quartz Crystal Microbalance with Dissipation Monitoring, Ellipsometry, and Surface Plasmon Resonance Study
Abstract
We have measured the time-resolved adsorption kinetics of the mussel adhesive protein (Mefp-1) on a nonpolar, methyl-terminated (thiolated) gold surface, using three independent techniques: quartz crystal microbalance with dissipation monitoring (QCM-D), surface plasmon resonance, and ellipsometry. The QCM-D and ellipsometry data shows that, after adsorption to saturation of Mefp-1, cross-linking of the protein layer using NaIO4 transforms it from an extended (approximately 20 nm), water-rich, and hydrogel-like state to a much thinner (approximately 5 nm), compact, and less water-rich state. Furthermore, we show how quantitative data about the thickness, shear elastic modulus, and shear viscosity of the protein film can be obtained with the QCM-D technique, even beyond the Sauerbrey regime, if frequency (f) and energy dissipation (D) measurements measured at multiple harmonics are combined with theoretical simulations using a Voight-based viscoelastic model. The modeling result was confirmed by substituting H2O for D2O. As expected, the D2O substitution does not influence the actual adsorption behavior, but resulted in expected differences in the estimated effective density and shear viscosity. These results provide new insight and understanding about the adsorption kinetics and crosslinking behavior of Mefp-1. They also demonstrate how the above three techniques complement each other for biomolecule adsorption studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
Use of quartz vibration for weighing thin films on a microbalance
Sauerbrey, G., & Sauerbrey, F. (1959) · The European Physical Journal A · Cited by 6,791
Voinova, M. V., Rodahl, M., Jonson, M., & Kasemo, B. (1999) · Physica Scripta · doi:10.1238/physica.regular.059a00391 · Cited by 1,587
Self-citationButtry, D. A., & Ward, M. D. (1992) · Chemical Reviews · doi:10.1021/cr00014a006 · Cited by 1,375
Rodahl, M., Höök, F., Krozer, A., Brzezinski, P., & Kasemo, B. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145396 · Cited by 1,296
Self-citationStenberg, E., Persson, B., Roos, H., & Urbaniczky, C. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90284-f · Cited by 1,059
Cell Proliferation in Carcinogenesis
Cohen, S. M., & Ellwein, L. B. (1990) · Science · doi:10.1126/science.2204108 · Cited by 1,050
Polyphenolic Substance of Mytilus edulis : Novel Adhesive Containing L-Dopa and Hydroxyproline
Waite, J. H., & Tanzer, M. L. (1981) · Science · doi:10.1126/science.212.4498.1038 · Cited by 1,050
Surface Specific Kinetics of Lipid Vesicle Adsorption Measured with a Quartz Crystal Microbalance
Keller, C. A., & Kasemo, B. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)74057-3 · Cited by 1,010
Self-citationHöök, F., Rodahl, M., Brzezinski, P., & Kasemo, B. (1998) · Langmuir · doi:10.1021/la970815u · Cited by 655
Self-citation
Cited by
The Transition from Stiff to Compliant Materials in Squid Beaks
Miserez, A., Schneberk, T., Sun, C., Zok, F. W., & Waite, J. H. (2008) · Science · doi:10.1126/science.1154117 · Cited by 453
Anderson, T. H., Yu, J., Estrada, A., Hammer, M. U., Waite, J. H., & Israelachvili, J. N. (2010) · Advanced Functional Materials · doi:10.1002/adfm.201000932 · Cited by 365
Metadata
- Authors
- Höök, F., Kasemo, B., Nylander, T., Fant, C., Sott, K., & Elwing, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-11-16
- Volume
- 73
- Issue
- 24
- Pages
- 5796-5804
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1992615890
- Cited by
- 1,162
- References
- 30
- FWCI
- 19.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.