The DOI matches its Crossref record.
Determination of Thiols by Capillary Electrophoresis with Amperometric Detection at a Coenzyme Pyrroloquinoline Quinone Modified Electrode
Abstract
A chemically modified electrode has been developed as a detector for the sensitive and selective determination of thiol-containing compounds following capillary electrophoresis separation. Electrodes were constructed by entrapment of the coenzyme pyrroloquinoline quinone (PQQ) into a polypyrrole (PPy) matrix on a 245-microm graphite electrode during electropolymerization of pyrrole in the presence of PQQ. PQQ serves as an efficient biocatalyst to mediate the oxidation of thiols at a substantially reduced overpotential relative to an unmodified electrode. Furthermore, this design takes advantage of the pH-dependent reversible electrochemical properties of PQQ, which facilitates optimization of separation and detection conditions. The PQQ/PPy-modified electrode was incorporated as an end-column detector, and a separation of homocysteine, cysteine, N-acetylcysteine, and glutathione was developed. Detection limits for these four thiols were determined to be 11, 23, 104, and 134 nM, respectively, with mass detection limits ranging from 0.29 to 3.48 fmol. The PQQ/PPy electrode was also found to be very reproducible in run-to-run, day-to-day, and electrode-to-electrode comparisons. The utility of this electrode was demonstrated for the detection of cysteine in dietary supplements and human urine, resulting in excellent agreement with reported values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Fluorescent Probes with Multiple Binding Sites for the Discrimination of Cys, Hcy, and GSH
Yin, C., Xiong, K., Huo, F., Salamanca, J. C., & Strongin, R. M. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201704084 · Cited by 493
Lin, W., Yuan, L., Cao, Z., Feng, Y., & Long, L. (2009) · Chemistry – A European Journal · doi:10.1002/chem.200802751 · Cited by 367
Recent Updates of Chemically Modified Electrodes in Analytical Chemistry
Zen, J., Senthil Kumar, A., & Tsai, D. (2003) · Electroanalysis · doi:10.1002/elan.200390130 · Cited by 338
Yin, G., Niu, T., Gan, Y., Yu, T., Yin, P., Chen, H., Zhang, Y., Li, H., & Yao, S. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201800485 · Cited by 314
Analytical determination of homocysteine: a review
Nekrassova, O. (2003) · Talanta · doi:10.1016/s0039-9140(03)00173-5 · Cited by 310
Determination of glutathione and glutathione disulfide in biological samples: An in-depth review
Monostori, P., Wittmann, G., Karg, E., & Túri, S. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.06.016 · Cited by 301
Pan, Y., Lei, S., Zhang, J., Qu, J., Huang, P., & Lin, J. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c04504 · Cited by 45
Metadata
- Authors
- Inoue, T., & Kirchhoff, J. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-02-14
- Volume
- 74
- Issue
- 6
- Pages
- 1349-1354
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2057226312
- Cited by
- 245
- References
- 0
- FWCI
- 5.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.