A Microchip-Based Multianalyte Assay System for the Assessment of Cardiac Risk

Christodoulides, Nick, Tran, Maiyen, Floriano, Pierre N., Rodriguez, Marc, Goodey, Adrian, Ali, Mehnaaz, Neikirk, Dean, McDevitt, John T.·2002·Analytical Chemistry

Abstract

The development of a novel chip-based multianalyte detection system with a cardiac theme is reported. This work follows the initial reports of "electronic taste chips" whereby multiple solution-phase analytes such as acids, bases, metal cations, and biological cofactors were detected and quantitated. The newly fashioned "cardiac chip" exploits a geometry that allows for isolation and entrapment of single polymeric spheres in micromachined pits while providing to each bead the rapid introduction of a series of reagents/washes through microfluidic structures. The combination of these miniaturized components fosters the completion of complex assays with short analysis times using small sample volumes. Optical signals derived from single beads are used to complete immunological tests that yield outstanding assay characteristics. The power and utility of this new methodology is demonstrated here for the simultaneous detection of the cardiac risk factors, C-reactive protein and interleukin-6, in human serum samples. This demonstration represents the first important step toward the development of a useful cardiac chip that targets numerous risk factors concurrently and one that can be customized readily for specific clinical settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac011150a

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 169

Metadata

Authors
Christodoulides, N., Tran, M., Floriano, P. N., Rodriguez, M., Goodey, A., Ali, M., Neikirk, D., & McDevitt, J. T.
Venue
Analytical Chemistry
Published
2002-05-30
Volume
74
Issue
13
Pages
3030-3036
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2014899914
Cited by
169
References
0
FWCI
13.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Microchip-Based Multianalyte Assay System for the Assessment of Cardiac Risk. https://app.cochat.ai/papers/10.1021/ac011150a
The paper
Christodoulides, N., Tran, M., Floriano, P. N., Rodriguez, M., Goodey, A., Ali, M., Neikirk, D., & McDevitt, J. T. (2002). A Microchip-Based Multianalyte Assay System for the Assessment of Cardiac Risk. Analytical Chemistry. https://doi.org/10.1021/ac011150a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.