The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
A fully automated immunoassay from whole blood on a disc
Abstract
A portable, disc-based, and fully automated enzyme-linked immuno-sorbent assay (ELISA) system is developed to test infectious diseases from whole blood. The innovative laser irradiated ferrowax microvalves and centrifugal microfluidics were utilized for the full integration of microbead-based suspension ELISA assays on a disc starting from whole blood. The concentrations of the antigen and the antibody of Hepatitis B virus (HBV), HBsAg and Anti-HBs respectively, were measured using the lab-on-a-disc (LOD). All the necessary reagents are preloaded on the disc and the total process of the plasma separation, incubation with target specific antigen or antibody coated microbeads, multiple steps of washing, enzyme reaction with substrates, and the absorbance detection could be finished within 30 minutes. Compared to the conventional ELISA, the operation time was dramatically reduced from over 2 hours to less than 30 minutes while the limit of detection was kept similar; e.g. the limit of detection of Anti-HBs tests were 8.6 mIU mL(-1) and 10 mIU mL(-1) for the disc-based and the conventional ELISA respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Design of a Compact Disk-like Microfluidic Platform for Enzyme-Linked Immunosorbent Assay
Lai, S., Wang, S., Luo, J., Lee, L. J., Yang, S.-T., & Madou, M. J. (2004) · Analytical Chemistry · doi:10.1021/ac0348322 · Cited by 418
One-step pathogen specific DNA extraction from whole blood on a centrifugal microfluidic device
Cho, Y.-K., Lee, J.-G., Park, J.-M., Lee, B.-S., Lee, Y., & Ko, C. (2007) · Lab on a Chip · doi:10.1039/b616115d · Cited by 312
Self-citation(2003) · Lab on a Chip · doi:10.1039/b313217j · Cited by 261
High-sensitivity miniaturized immunoassays for tumor necrosis factor ? using microfluidic systems
Cesaro-Tadic, S., Dernick, G., Juncker, D., Buurman, G., Kropshofer, H., Michel, B., Fattinger, C., & Delamarche, E. (2004) · Lab on a Chip · doi:10.1039/b408964b · Cited by 203
A Microchip-Based Multianalyte Assay System for the Assessment of Cardiac Risk
Christodoulides, N., Tran, M., Floriano, P. N., Rodriguez, M., Goodey, A., Ali, M., Neikirk, D., & McDevitt, J. T. (2002) · Analytical Chemistry · doi:10.1021/ac011150a · Cited by 169
Honda, N., Lindberg, U., Andersson, P., Hoffmann, S., & Takei, H. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.053348 · Cited by 156
Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detection
Sato, K., Yamanaka, M., Hagino, T., Tokeshi, M., Kimura, H. M., & Kitamori, T. (2004) · Lab on a Chip · doi:10.1039/b411356j · Cited by 112
Bead-based immunoassays using a micro-chip flow cytometer
Holmes, D., She, J. K., Roach, P. L., & Morgan, H. (2007) · Lab on a Chip · doi:10.1039/b707507n · Cited by 105
Herrmann, M., Veres, T., & Tabrizian, M. (2008) · Analytical Chemistry · doi:10.1021/ac800427z · Cited by 47
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Centrifugal microfluidics for biomedical applications
Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K. (2010) · Lab on a Chip · doi:10.1039/b924109d · Cited by 731
Self-citationLatest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Metadata
- Authors
- Lee, B. S., Lee, J.-N., Park, J.-M., Lee, J.-G., Kim, S., Cho, Y.-K., & Ko, C.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 11
- Pages
- 1548
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1965041557
- Cited by
- 302
- References
- 10
- FWCI
- 14.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A fully automated immunoassay from whole blood on a disc. https://app.cochat.ai/papers/10.1039/b820321k
- The paper
- Lee, B. S., Lee, J.-N., Park, J.-M., Lee, J.-G., Kim, S., Cho, Y.-K., & Ko, C. (2009). A fully automated immunoassay from whole blood on a disc. Lab on a Chip. https://doi.org/10.1039/b820321k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.