The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A Microfabrication-Based Dynamic Array Cytometer
Abstract
We have developed a microfabricated device for use in parallel luminescent single-cell assays that can sort populations upon the basis of dynamic functional responses to stimuli. This device is composed of a regular array of noncontact single-cell traps. These traps use dielectrophoresis to stably confine cells and hold them against disrupting fluid flows. Using quantitative modeling, we have designed traps with a novel asymmetric extruded-quadrupole geometry. This new trap can be physically arrayed and electrically addressed, enabling our cytometer. Situating an array of these traps in a microchannel, we have introduced cells into the array and demonstrated observation of fluorescent dynamic responses followed by sorting. Such a device has potential for use in investigating functional processes, as revealed by temporal behavior, in large numbers of single cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inositol trisphosphate and calcium signalling
Berridge, M. J. (1993) · Nature · doi:10.1038/361315a0 · Cited by 6,545
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786
A N EW A PPROACH TO D ECODING L IFE : Systems Biology
Ideker, T., Galitski, T., & Hood, L. (2001) · Annual Review of Genomics and Human Genetics · doi:10.1146/annurev.genom.2.1.343 · Cited by 1,664
Cited by
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Self-citationMicrofluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Self-citationProbing the role of multicellular organization in three-dimensional microenvironments
Albrecht, D. R., Underhill, G. H., Wassermann, T. B., Sah, R. L., & Bhatia, S. N. (2006) · Nature Methods · doi:10.1038/nmeth873 · Cited by 552
Large-Scale Single-Cell Trapping And Imaging Using Microwell Arrays
Rettig, J. R., & Folch, A. (2005) · Analytical Chemistry · doi:10.1021/ac0505977 · Cited by 502
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Di Carlo, D., Aghdam, N., & Lee, L. P. (2006) · Analytical Chemistry · doi:10.1021/ac060541s · Cited by 458
Microfluidics for flow cytometric analysis of cells and particles
Huh, D., Gu, W., Kamotani, Y., Grotberg, J. B., & Takayama, S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/3/r02 · Cited by 396
Dielectrophoresis for manipulation of micro/nano particles in microfluidic systems
Zhang, C., Khoshmanesh, K., Mitchell, A., & Kalantar-zadeh, K. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2922-6 · Cited by 305
Metadata
- Authors
- Voldman, J., Gray, M. L., Toner, M., & Schmidt, M. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-07-10
- Volume
- 74
- Issue
- 16
- Pages
- 3984-3990
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1993390786
- Cited by
- 328
- References
- 3
- FWCI
- 12.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.