The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Surface Modification of Poly(dimethylsiloxane) Microfluidic Devices by Ultraviolet Polymer Grafting
Abstract
Poly(dimethylsiloxane) (PDMS)-based microfluidic devices are increasing in popularity due to their ease of fabrication and low costs. Despite this, there is a tremendous need for strategies to rapidly and easily tailor the surface properties of these devices. We demonstrate a one-step procedure to covalently link polymers to the surface of PDMS microchannels by ultraviolet graft polymerization. Acrylic acid, acrylamide, dimethylacrylamide, 2-hydroxylethyl acrylate, and poly(ethylene glycol)monomethoxyl acrylate were grafted onto PDMS to yield hydrophilic surfaces. Water droplets possessed contact angles as low as 45 degrees on the grafted surfaces. Microchannels constructed from the grafted PDMS were readily filled with aqueous solutions in contrast to devices composed of native PDMS. The grafted surfaces also displayed a substantially reduced adsorption of two test peptides compared to that of oxidized PDMS. Microchannels with grafted surfaces exhibited electroosmotic mobilities intermediate to those displayed by native and oxidized PDMS. Unlike the electroosmotic mobility of oxidized PDMS, the electroosmotic mobility of the grafted surfaces remained stable upon exposure to air. The electrophoretic resolution of two test peptides in the grafted microchannels was considerably improved compared to that in microchannels composed of oxidized PDMS. By using the appropriate monomer, it should be possible to use UV grafting to impart a variety of surface properties to PDMS microfluidics devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Protein Kinase C Contains a Pseudosubstrate Prototope in Its Regulatory Domain
House, C., & Kemp, B. E. (1987) · Science · doi:10.1126/science.3686012 · Cited by 997
Polymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795
Surface modification of polymers for medical applications
Ikada, Y. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90025-6 · Cited by 674
Polymer surface modification and characterization
Chan, C. (1993) · Rare & Special e-Zone (The Hong Kong University of Science and Technology) · Cited by 573
Bélanger, M., & Marois, Y. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1043 · Cited by 471
GCN5-Related N-Acetyltransferases: A Structural Overview
Dyda, F., Klein, D. C., & Hickman, A. B. (2000) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.29.1.81 · Cited by 455
Avdeef, A., Comer, J. E. A., & Thomson, S. J. (1993) · Analytical Chemistry · doi:10.1021/ac00049a010 · Cited by 256
In vitro selection of an allosteric ribozyme that transduces analytes to amplicons
Robertson, M. P., & Ellington, A. (1999) · Nature Biotechnology · doi:10.1038/5236 · Cited by 244
Duffy, D. C., Schueller, O. J. A., Brittain, S. T., & Whitesides, G. M. (1999) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/9/3/301 · Cited by 205
Linder, V., Verpoorte, E., Thormann, W., de Rooij, N. F., & Sigrist, H. (2001) · Analytical Chemistry · doi:10.1021/ac010421e · Cited by 173
Grzybowski, B. A., Haag, R., Bowden, N. B., et al. (1998) · Analytical Chemistry · doi:10.1021/ac9807621 · Cited by 90
Surface modification of polyethylene balloon catheters for local drug delivery
Richey, T., Iwata, H., OOWAKI, H., Uchida, E., Matsuda, S., & Ikada, Y. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00281-1 · Cited by 85
Uchida, E., Uyama, Y., & Ikada, Y. (1993) · Journal of Applied Polymer Science · doi:10.1002/app.1993.070470305 · Cited by 68
Belder, D., & Warnke, J. (2001) · Langmuir · doi:10.1021/la010115w · Cited by 22
Cited by
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Multiphase microfluidics: from flow characteristics to chemical and materials synthesis
Günther, A., & Jensen, K. F. (2006) · Lab Chip · doi:10.1039/b609851g · Cited by 983
Recent developments in PDMS surface modification for microfluidic devices
Zhou, J., Ellis, A. V., & Voelcker, N. H. (2010) · ELECTROPHORESIS · doi:10.1002/elps.200900475 · Cited by 857
PDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M. P., Salieb-Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 853
Biocompatible polymer materials: Role of protein–surface interactions
Chen, H., Yuan, L., Song, W., Wu, Z., & Li, D. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.006 · Cited by 706
Metadata
- Authors
- Hu, S., Ren, X., Bachman, M., Sims, C. E., Li, G. P., & Allbritton, N.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-06-22
- Volume
- 74
- Issue
- 16
- Pages
- 4117-4123
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2090803851
- Cited by
- 418
- References
- 19
- FWCI
- 15.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.