High-Efficiency On-Line Solid-Phase Extraction Coupling to 15−150-μm-i.d. Column Liquid Chromatography for Proteomic Analysis
The DOI matches its Crossref record.
Abstract
The ability to manipulate and effectively utilize small proteomic samples is important for analyses using liquid chromatography (LC) in combination with mass spectrometry (MS) and becomes more challenging for very low flow rates due to extra column volume effects on separation quality. Here we report on the use of commercial switching valves (150-microm channels) for implementing the on-line coupling of capillary LC columns operated at 10,000 psi with relatively large solid-phase extraction (SPE) columns. With the use of optimized column connections, switching modes, and SPE column dimensions, high-efficiency on-line SPE-capillary and nanoscale LC separations were obtained demonstrating peak capacities of approximately 1000 for capillaries having inner diameters between 15 and 150 microm. The on-line coupled SPE columns increased the sample processing capacity by approximately 400-fold for sample solution volume and approximately 10-fold for sample mass. The proteomic applications of this on-line SPE-capillary LC system were evaluated for analysis of both soluble and membrane protein tryptic digests. Using an ion trap tandem MS it was typically feasible to identify 1100-1500 unique peptides in a 5-h analysis. Peptides extracted from the SPE column and then eluted from the LC column covered a hydrophilicity/hydrophobicity range that included an estimated approximately 98% of all tryptic peptides. The SPE-capillary LC implementation also facilitates automation and enables use of both disposable SPE columns and electrospray emitters, providing a robust basis for automated proteomic analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Keshishian, H., Addona, T., Burgess, M., Kuhn, E., & Carr, S. A. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700354-mcp200 · Cited by 684
Zhu, Y., Piehowski, P. D., Zhao, R., Chen, J., Shen, Y., Moore, R. J., Shukla, A. K., Petyuk, V. A., Campbell-Thompson, M., Mathews, C. E., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03367-w · Cited by 587
Self-citationFast, comprehensive two-dimensional liquid chromatography
Stoll, D. R., Li, X., Wang, X., Carr, P. W., Porter, S. E. G., & Rutan, S. C. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.08.054 · Cited by 396
Zhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Self-citationAdvances in proteomics data analysis and display using an accurate mass and time tag approach
Zimmer, J. S. D., Monroe, M. E., Qian, W., & Smith, R. D. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20071 · Cited by 304
Self-citationTang, K., Page, J. S., & Smith, R. D. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.04.034 · Cited by 262
Self-citationZhu, Y., Dou, M., Piehowski, P. D., Liang, Y., Wang, F., Chu, R. K., Chrisler, W. B., Smith, J. N., Schwarz, K. C., Shen, Y., et al. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000686 · Cited by 147
Self-citationHu, L., Boos, K.-S., Ye, M., Wu, R., & Zou, H. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.05.030 · Cited by 56
Metadata
- Authors
- Shen, Y., Moore, R. J., Zhao, R., Blonder, J., Auberry, D. L., Masselon, C., Paša-Tolić, L., Hixson, K. K., Auberry, K. J., & Smith, R. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-06-07
- Volume
- 75
- Issue
- 14
- Pages
- 3596-3605
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1981270845
- Cited by
- 97
- References
- 0
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.