The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Femtomolar Detection of Prostate-Specific Antigen: An Immunoassay Based on Surface-Enhanced Raman Scattering and Immunogold Labels
Abstract
A novel reagent for low-level detection in immunoadsorbent assays is described. The reagent consists of gold nanoparticles modified to integrate bioselective species (e.g., antibodies) with molecular labels for the generation of intense, biolyte-selective surface-enhanced Raman scattering (SERS) responses in immunoassays and other bioanalytical applications. The reagent is constructed by coating gold nanoparticles (30 nm) with a monolayer of an intrinsically strong Raman scatterer. These monolayer-level labels are bifunctional by design and contain disulfides for chemisorption to the nanoparticle surface and succinimides for coupling to the bioselective species. There are two important elements in this label design; it both minimizes the separation between label and particle surface and maximizes the number of labels on each particle. This approach to labeling also exploits several other advantages of SERS-based labels: narrow spectral bandwidth, resistance to photobleaching and quenching, and long-wavelength excitation of multiple labels with a single excitation source. The strengths of this strategy are demonstrated in the detection of free prostate-specific antigen (PSA) using a sandwich assay format based on monoclonal antibodies. Detection limits of approximately 1 pg/mL in human serum and approximately 4 pg/mL in bovine serum albumin have been achieved with a spectrometer readout time of 60 s. The extension of the method to multianalyte assays (e.g., the simultaneous determination of the many complexed forms of PSA) is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-Dimensional Fluorescence Spectroscopy: A New Tool for On-Line Bioprocess Monitoring
Marose, S., Lindemann, C., & Scheper, T. (1998) · Biotechnology Progress · doi:10.1021/bp970124o · Cited by 190
Cited by
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Localized surface plasmon resonance: Nanostructures, bioassays and biosensing—A review
Petryayeva, E., & Krull, U. J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.020 · Cited by 1,379
Computationally Guided Photothermal Tumor Therapy Using Long-Circulating Gold Nanorod Antennas
von Maltzahn, G., Park, J.-H., Agrawal, A., Bandaru, N. K., Das, S. K., Sailor, M. J., & Bhatia, S. N. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-4242 · Cited by 1,051
SERS as a bioassay platform: fundamentals, design, and applications
Porter, M. D., Lipert, R. J., Siperko, L. M., Wang, G., & Narayanan, R. (2008) · Chemical Society Reviews · doi:10.1039/b708461g · Cited by 580
Self-citationMultiplex in vitro detection using SERS
Laing, S., Gracie, K., & Faulds, K. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00644a · Cited by 361
Metadata
- Authors
- Grubisha, D. S., Lipert, R. J., Park, H.-Y., Driskell, J., & Porter, M. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-09-23
- Volume
- 75
- Issue
- 21
- Pages
- 5936-5943
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2011166834
- Cited by
- 779
- References
- 1
- FWCI
- 13.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.