The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Improving Fluorescent DNAzyme Biosensors by Combining Inter- and Intramolecular Quenchers
Abstract
A previously reported DNAzyme-based biosensor for Pb(2+) has shown high sensitivity and selectivity at 4 degrees C. In the system, the substrate and the enzyme strand of the DNAzyme are labeled with a fluorophore and a quencher, respectively. In the presence of Pb(2+), the substrate strand is cleaved by the enzyme strand, and the release of the cleaved fragment results in significant fluorescence increase. However, the performance of the sensor decreases considerably if the temperature is raised to room temperature because of high background fluorescence. A careful analysis of the sensor system, including measurement of the melting curve and fluorescence resonance energy-transfer (FRET) study of the free substrate, suggests that a fraction of the fluorophore-labeled substrate strand is dissociated from the enzyme strand, resulting in elevated background fluorescence signals at room temperature. To overcome this problem, we designed a new sensor system by introducing both inter- and intramolecular quenchers. The design was aided by the FRET study that showed the dissociated substrate maintained a random coil conformation with an end-to-end distance of approximately 39 A, which is much shorter than that of the fully extended DNA. With this new design, the background fluorescence was significantly suppressed, with 660% increase of fluorescence intensity as compared to 60% increase for the previous design. This suppression of background fluorescence signals was achieved without losing selectivity of the sensor. The new design makes it possible to use the sensor for practical applications in a wide temperature range. The design principle presented here should be applicable to other nucleic acid-based biosensors to decrease background fluorescence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mfold web server for nucleic acid folding and hybridization prediction
Zuker, M. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg595 · Cited by 13,404
Cited by
Liu, J., & Lu, Y. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702006 · Cited by 593
Self-citationIn vitro selection of a sodium-specific DNAzyme and its application in intracellular sensing
Torabi, S.-F., Wu, P., McGhee, C. E., Chen, L., Hwang, K., Zheng, N., Cheng, J., & Lu, Y. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1420361112 · Cited by 347
Self-citationLake, R. J., Yang, Z., Zhang, J., & Lu, Y. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00419 · Cited by 281
Self-citationWu, Y., Torabi, S.-F., Lake, R. J., Hong, S., Yu, Z., Wu, P., Yang, Z., Nelson, K., Guo, W., Pawel, G. T., et al. (2023) · Science Advances · doi:10.1126/sciadv.ade7622 · Cited by 91
Self-citation
Metadata
- Authors
- Liu, J., & Lu, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-11-01
- Volume
- 75
- Issue
- 23
- Pages
- 6666-6672
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1977680898
- Cited by
- 199
- References
- 1
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving Fluorescent DNAzyme Biosensors by Combining Inter- and Intramolecular Quenchers. https://app.cochat.ai/papers/10.1021/ac034924r
- The paper
- Liu, J., & Lu, Y. (2003). Improving Fluorescent DNAzyme Biosensors by Combining Inter- and Intramolecular Quenchers. Analytical Chemistry. https://doi.org/10.1021/ac034924r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.