CoChat

Development of a Solid-Phase Extraction-HPLC/Single Quadrupole MS Method for Quantification of Perfluorochemicals in Whole Blood

Kärrman, Anna, van Bavel, Bert, Järnberg, Ulf, Hardell, Lennart, Lindström, Gunilla · 2005 · Analytical Chemistry
Cited by 105

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A method for the determination of perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA) simultaneously with 10 closely related perfluorochemicals (PFCs) in human whole blood was developed and validated. PFOS and PFOA are used in various applications, for example, as surfactants and plastic additives, and are subject to environmental and health research due to their persistence. The main part of the data on PFCs in human blood is from serum samples, analyzed mainly by ion pair extraction followed by high-performance liquid chromatography (HPLC) and negative electrospray (ESI) tandem mass spectrometry (MS/MS). The analytical method developed here is suitable for human whole blood and involves solid-phase extraction (SPE) and HPLC negative electrospray single quadrupole mass spectrometry (HPLC/ES-MS). A whole blood aliquot was treated with formic acid and extracted on a octadecyl (C18) SPE column. The PFCs were isolated with methanol, and quantification was performed using single quadrupole mass spectrometry and perfluoroheptanoic acid as internal standard. Validation was performed in the range 0.3-194 ng/mL with recovery between 64 and 112% and limit of detection in the 0.1-0.5 ng/mL range for 11 of the 12 PFCs studied. We applied this method to 20 whole blood samples collected in 1997-2000 from the Swedish population in the ages 24-72. Eleven of the 12 PFCs were detected, and they were quantitatively and qualitatively confirmed using triple quadrupole LC/MS/MS analysis. PFOS, perfluorooctanesulfonamide, perfluorohexanesulfonate, PFOA and perfluorononanoic acid were quantified in all samples. In addition, perfluorohexanoic acid, perfluorodecanoic acid, perfluorodecanesulfonate, perfluoroundecanoic acid, perfluorododecanoic acid, and perfluorotetradecanoic acid were detected in some samples. This study shows that SPE and single quadrupole MS can be applied for extraction and quantification of PFCs in human whole blood, resulting in selectivity and low detection limits.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac049023c

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 105

Metadata

Authors
Kärrman, A., van Bavel, B., Järnberg, U., Hardell, L., & Lindström, G.
Venue
Analytical Chemistry
Published
2004-12-30
Volume
77
Issue
3
Pages
864-870
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2148995957
Cited by
105
References
3
FWCI
6.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.