The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Glucose Sensing Using Near-Infrared Surface-Enhanced Raman Spectroscopy: Gold Surfaces, 10-Day Stability, and Improved Accuracy
Abstract
This research presents the achievement of significant milestones toward the development of a minimally invasive, continuously monitoring, glucose-sensing platform based on the optical quantitation of glucose in interstitial fluid. We expand our initial successes in the measurement of glucose by surface-enhanced Raman scattering (SERS), demonstrating substantial improvements not only in the quality and optical properties of the substrate system itself but also in the robustness of the measurement methodology and the amenability of the technique to compact, diode laser-based instrumentation. Herein, we compare the long-term stability of gold to silver film over nanosphere (AuFON, AgFON) substrates functionalized with a partitioning self-assembled monolayer (SAM) using both electrochemical and SERS measurements. AuFONs were found to be stable for a period of at least 11 days. The switch to AuFONs not only provides a more stable surface for SAM formation but also yields better chemometric results, with improved calibration and validation over a range of 0.5-44 mM (10-800 mg/dL). Measured values for glucose concentrations in phosphate-buffered saline (pH approximately 7.4) based on 160 independent SERS measurements on AuFONs have a root-mean-square error of prediction of 2.7 mM (49.5 mg/dL), with 91% of the values falling within an extended A-B range on an expanded Clarke error grid. Furthermore, AuFONs exhibit surface plasmon resonances at longer wavelengths than similar AgFONs, which make them more efficient for SERS at near-infrared wavelengths, enabling the use of low-power diode lasers in future devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
Toward a Glucose Biosensor Based on Surface-Enhanced Raman Scattering
Shafer-Peltier, K. E., Haynes, C. L., Glucksberg, M. R., & Van Duyne, R. P. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028255v · Cited by 653
Self-citationEnzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Yonzon, C. R., Haynes, C. L., Zhang, X., Walsh, & Van Duyne, R. P. (2004) · Analytical Chemistry · doi:10.1021/ac035134k · Cited by 376
Self-citation
Cited by
Localized Surface Plasmon Resonance Spectroscopy and Sensing
Willets, K. A., & Van Duyne, R. P. (2007) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.58.032806.104607 · Cited by 6,171
Self-citationSurface-Enhanced Raman Spectroscopy
Stiles, P. L., Dieringer, J. A., Shah, N. C., & Van Duyne, R. P. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112814 · Cited by 3,178
Self-citationLocalized surface plasmon resonance: Nanostructures, bioassays and biosensing—A review
Petryayeva, E., & Krull, U. J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.020 · Cited by 1,379
Surface-Enhanced Raman Spectroscopy
Haynes, C. L., McFarland, A. D., & Van Duyne, R. P. (2005) · Analytical Chemistry · doi:10.1021/ac053456d · Cited by 1,144
Controlled Plasmonic Nanostructures for Surface-Enhanced Spectroscopy and Sensing
Camden, J. P., Dieringer, J. A., Zhao, J., & Van Duyne, R. P. (2008) · Accounts of Chemical Research · doi:10.1021/ar800041s · Cited by 730
Self-citation
Metadata
- Authors
- Stuart, D. A., Yonzon, C. R., Zhang, X., Lyandres, O., Shah, N. C., Glucksberg, M. R., Walsh, J. T., & Van Duyne, R. P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-05-24
- Volume
- 77
- Issue
- 13
- Pages
- 4013-4019
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2046853337
- Cited by
- 182
- References
- 4
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.