CoChat

On-Line Back-Extraction Field-Amplified Sample Injection Method for Directly Analyzing Cocaine and Thebaine in the Extractants by Solvent Microextraction

Fang, Huaifang, Zeng, Zhaorui, Liu, Lan, Pang, Daiwen · 2006 · Analytical Chemistry
Cited by 36

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

This paper describes a novel method that applies on-line back-extraction field-amplified sample injection (OLBE-FASI) to the extractants by solvent microextraction (SME) in capillary zone electrophoresis (CZE). To our knowledge, it provides the first report that the water-immiscible solvent samples were directly analyzed by CZE. The water-immiscible solvent sample, sealed with a water plug in the sample vial, was used for direct electroinjection. The water plug with a moderate content of organic solvent, low-conductivity, and the presence of a small amount of H+ provided the highest sensitivity for analyzing positively chargeable compounds, such as cocaine and thebaine. The linear range was at least 2 orders of magnitude, with the square of the correlation coefficient (r2) > 0.9999, and a separate calibration over the range 0.016-10 microg/mL showed the linear range to be approaching 3 orders of magnitude. Detection limits were in the range of 2-10 ng/mL. Because the need to perform solvent exchange (from organic to aqueous solution) was eliminated, the OLBE-FASI method could be conveniently coupled with SME. In the present work, SME-OLBE-FASI-CE was validated for quantitative purposes, and applications to human urine were demonstrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0516537

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 36

Metadata

Authors
Fang, H., Zeng, Z., Liu, L., & Pang, D.
Venue
Analytical Chemistry
Published
2005-12-22
Volume
78
Issue
4
Pages
1257-1263
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2074318054
Cited by
36
References
3
FWCI
1.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On-Line Back-Extraction Field-Amplified Sample Injection Method for Directly Analyzing Cocaine and Thebaine in the Extractants by Solvent Microextraction. https://app.cochat.ai/papers/10.1021/ac0516537
The paper
Fang, H., Zeng, Z., Liu, L., & Pang, D. (2006). On-Line Back-Extraction Field-Amplified Sample Injection Method for Directly Analyzing Cocaine and Thebaine in the Extractants by Solvent Microextraction. Analytical Chemistry. https://doi.org/10.1021/ac0516537

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.