Capillary LC Coupled with High-Mass Measurement Accuracy Mass Spectrometry for Metabolic Profiling
The DOI matches its Crossref record.
Abstract
We have developed an efficient and robust high-pressure capillary LC-MS method for the identification of large numbers of metabolites in biological samples using both positive and negative ESI modes. Initial efforts focused on optimizing the separation conditions for metabolite extracts using various LC stationary phases in conjunction with multiple mobile-phase systems, as applied to the separation of 45 metabolite standards. The optimal mobile and stationary phases of those tested were determined experimentally (in terms of peak shapes, theoretical plates, retention of small, polar compounds, etc.), and both linear and exponential gradients were applied in the study of metabolite extracts from the cyanobacterium Cyanothece sp. ATCC 51142. Finally, an automated dual-capillary LC system was constructed and evaluated for the effectiveness and reproducibility of the chromatographic separations using the above samples. When coupled with a commercial LTQ-orbitrap MS, approximately 900 features were reproducibly detected from Cyanothece sp. ATCC 51142 metabolite extracts. In addition, 12 compounds were tentatively identified, based on accurate mass, isotopic distribution, and MS/MS information.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
Zhu, Z.-J., Schultz, A. W., Wang, J., Johnson, C. H., Yannone, S. M., Patti, G. J., & Siuzdak, G. (2013) · Nature Protocols · doi:10.1038/nprot.2013.004 · Cited by 477
Diamond, D. L., Syder, A. J., Jacobs, J. M., Sorensen, C. M., Walters, K.-A., Proll, S. C., McDermott, J. E., Gritsenko, M. A., Zhang, Q., Zhao, R., et al. (2010) · PLoS Pathogens · doi:10.1371/journal.ppat.1000719 · Cited by 412
Self-citationHigh-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
LC-MS-based methodology for global metabolite profiling in metabonomics/metabolomics
Theodoridis, G., Gika, H. G., & Wilson, I. D. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.01.008 · Cited by 371
Metadata
- Authors
- Ding, J., Sorensen, C. M., Zhang, Q., Jiang, H., Jaitly, N., Livesay, E. A., Shen, Y., Smith, R. D., & Metz, T. O.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-07-18
- Volume
- 79
- Issue
- 16
- Pages
- 6081-6093
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2049948296
- Cited by
- 52
- References
- 0
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capillary LC Coupled with High-Mass Measurement Accuracy Mass Spectrometry for Metabolic Profiling. https://app.cochat.ai/papers/10.1021/ac070080q
- The paper
- Ding, J., Sorensen, C. M., Zhang, Q., Jiang, H., Jaitly, N., Livesay, E. A., Shen, Y., Smith, R. D., & Metz, T. O. (2007). Capillary LC Coupled with High-Mass Measurement Accuracy Mass Spectrometry for Metabolic Profiling. Analytical Chemistry. https://doi.org/10.1021/ac070080q
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.