Colloidal Graphite-Assisted Laser Desorption/Ionization MS and MSn of Small Molecules. 2. Direct Profiling and MS Imaging of Small Metabolites from Fruits
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Due to a high background in the low-mass region, conventional MALDI is not as useful for detecting small molecules (molecular masses <500 Da) as it is for large ones. Also, spatial inhomogeneity that is inherent to crystalline matrixes can degrade resolution in imaging mass spectrometry (IMS). In this study, colloidal graphite was investigated as an alternative matrix for laser desorption/ionization (GALDI) in IMS. We demonstrate its advantages over conventional MALDI in the detection of small molecules such as organic acids, flavonoids, and oligosaccharides. GALDI provides good sensitivity for such small molecules. The detection limit of fatty acids and flavonoids in the negative-ion mode are in the low-femtomole range. Molecules were detected directly and identified by comparing the MS and MS/MS spectra with those of standards. Various fruits were chosen to evaluate the practical utility of GALDI since many types of small molecules are present in them. Distribution of these small molecules in the fruit was investigated by using IMS and IMS/MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometry
Tanaka, K., Waki, H., Ido, Y., Akita, S., Yoshida, Y., Yoshida, T., & Matsuo, T. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290020802 · Cited by 3,175
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234
Int. J. Mass Spectrom. Ion Processes
(1990) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(90)80022-u · Cited by 1,003
Schwartz, S. A., Reyzer, M. L., & Caprioli, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.505 · Cited by 646
Wiseman, J. M., Ifa, D. R., Song, Q., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200602449 · Cited by 626
Mass spectrometry of synthetic polymers by UV-matrix-assisted laser desorption/ionization
Bahr, U., Deppe, A., Karas, M., Hillenkamp, F., & Giessmann, U. (1992) · Analytical Chemistry · doi:10.1021/ac00046a036 · Cited by 487
Analytical Chemistry of Fruit BioflavonoidsA Review
Robards, K., & Antolovich, M. (1997) · The Analyst · doi:10.1039/a606499j · Cited by 436
MCLEAN, J. A. J., Stumpo, K. A., & Russell, D. H. (2005) · Journal of the American Chemical Society · doi:10.1021/ja043907w · Cited by 419
Growing range of correlated motion in a polymer melt on cooling towards the glass transition
Bennemann, C., Donati, C., Baschnagel, J., & Glotzer, S. C. (1999) · Nature · doi:10.1038/20406 · Cited by 409
Cited by
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
Han, X., Yang, K., & Gross, R. W. (2012) · Mass Spectrometry Reviews · doi:10.1002/mas.20342 · Cited by 530
Sample preparation for mass spectrometry imaging: Small mistakes can lead to big consequences
Goodwin, R. J. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.012 · Cited by 313
Mass spectrometry imaging for plant biology: a review
Boughton, B. A., Thinagaran, D., Sarabia, D., Bacic, A., & Roessner, U. (2016) · Phytochemistry Reviews · doi:10.1007/s11101-015-9440-2 · Cited by 300
Nemes, P., Barton, A. A., Li, Y., & Vertes, A. (2008) · Analytical Chemistry · doi:10.1021/ac8004082 · Cited by 244
Mass spectrometry imaging of plant metabolites – principles and possibilities
Bjarnholt, N., Li, B., D'Alvise, J., & Janfelt, C. (2014) · Nat. Prod. Rep. · doi:10.1039/c3np70100j · Cited by 225
Nemes, P., Barton, A. A., & Vertes, A. (2009) · Analytical Chemistry · doi:10.1021/ac900745e · Cited by 223
Nemes, P., Woods, A. S., & Vertes, A. (2010) · Analytical Chemistry · doi:10.1021/ac902245p · Cited by 211
Kim, Y.-K., Na, H.-K., Kwack, S.-J., Ryoo, S.-R., Lee, Y., Hong, S., Hong, S., Jeong, Y., & Min, D.-H. (2011) · ACS Nano · doi:10.1021/nn200245v · Cited by 190
Sample Preparation for Mass Spectrometry Imaging of Plant Tissues: A Review
Dong, Y., Li, B., Malitsky, S., Rogachev, I., Aharoni, A., Kaftan, F., Svatoš, A., & Franceschi, P. (2016) · Frontiers in Plant Science · doi:10.3389/fpls.2016.00060 · Cited by 179
Protein and peptides in pictures: Imaging with MALDI mass spectrometry
Goodwin, R. J. A., Pennington, S. R., & Pitt, A. R. (2008) · PROTEOMICS · doi:10.1002/pmic.200800320 · Cited by 164
Metadata
- Authors
- Zhang, H., Cha, S., & Yeung, E. S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-08-01
- Volume
- 79
- Issue
- 17
- Pages
- 6575-6584
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1990659485
- Cited by
- 164
- References
- 23
- FWCI
- 6.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.