SlipChip for Immunoassays in Nanoliter Volumes
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This article describes a SlipChip-based approach to perform bead-based heterogeneous immunoassays with multiple nanoliter-volume samples. As a potential device to analyze the output of the chemistrode, the performance of this platform was tested using low concentrations of biomolecules. Two strategies to perform the immunoassay in the SlipChip were tested: (1) a unidirectional slipping method to combine the well containing a sample with a series of wells preloaded with reagents and (2) a back-and-forth slipping method to introduce a series of reagents to a well containing the sample by reloading and slipping the well containing the reagent. The SlipChips were fabricated with hydrophilic surfaces on the interior of the wells and with hydrophobic surfaces on the face of the SlipChip to enhance filling, transferring, and maintaining aqueous solutions in shallow wells. Nanopatterning was used to increase the hydrophobic nature of the SlipChip surface. Magnetic beads containing the capture antibody were efficiently transferred between wells and washed by serial dilution. An insulin immunoenzymatic assay showed a detection of limit of approximately 13 pM. A total of 48 droplets of nanoliter volume were analyzed in parallel, including an on-chip calibration. The design of the SlipChip is flexible to accommodate other types of immunoassays, both heterogeneous and homogeneous. This work establishes the possibility of using SlipChip-based immunoassays in small volumes for a range of possible applications, including analysis of plugs from a chemistrode, detection of molecules from single cells, and diagnostic monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693
Self-citationDu, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Self-citation
Cited by
Analytical detection techniques for droplet microfluidics—A review
Zhu, Y., & Fang, Q. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.04.064 · Cited by 365
Electrochemical sensors based on graphene materials
Gan, T., & Hu, S. (2011) · Microchimica Acta · doi:10.1007/s00604-011-0639-7 · Cited by 349
Shen, F., Du, W., Kreutz, J. E., Fok, A., & Ismagilov, R. F. (2010) · Lab on a Chip · doi:10.1039/c004521g · Cited by 295
Self-citationHighly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
Shen, F., Davydova, E. K., Du, W., Kreutz, J. E., Piepenburg, O., & Ismagilov, R. F. (2011) · Analytical Chemistry · doi:10.1021/ac200247e · Cited by 240
Self-citation
Metadata
- Authors
- Liu, W., Chen, D., Du, W., Nichols, K. P., & Ismagilov, R. F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-03-24
- Volume
- 82
- Issue
- 8
- Pages
- 3276-3282
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1988554258
- Cited by
- 102
- References
- 3
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.