Evaluation of Peak Picking Quality in LC−MS Metabolomics Data
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The output of LC-MS metabolomics experiments consists of mass-peak intensities identified through a peak-picking/alignment procedure. Besides imperfections in biological samples and instrumentation, data accuracy is highly dependent on the applied algorithms and their parameters. Consequently, quality control (QC) is essential for further data analysis. Here, we present a QC approach that is based on discrepancies between replicate samples. First, the quantile normalization of per-sample log-signal distributions is applied to each group of biologically homogeneous samples. Next, the overall quality of each replicate group is characterized by the Z-transformed correlation coefficients between samples. This general QC allows a tuning of the procedure's parameters which minimizes the inter-replicate discrepancies in the generated output. Subsequently, an in-depth QC measure detects local neighborhoods on a template of aligned chromatograms that are enriched by divergences between intensity profiles of replicate samples. These neighborhoods are determined through a segmentation algorithm. The retention time (RT)-m/z positions of the neighborhoods with local divergences are indicative of either: incorrect alignment of chromatographic features, technical problems in the chromatograms, or to a true biological discrepancy between replicates for particular metabolites. We expect this method to aid in the accurate analysis of metabolomics data and in the development of new peak-picking/alignment procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
van den Berg, R. A., Hoefsloot, H. C., Westerhuis, J. A., Smilde, A. K., & van der Werf, M. J. (2006) · BMC Genomics · doi:10.1186/1471-2164-7-142 · Cited by 2,450
Data processing for mass spectrometry-based metabolomics
Katajamaa, M., & Orešič, M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.021 · Cited by 616
Cited by
Zhou, B., Xiao, J. F., Tuli, L., & Ressom, H. W. (2011) · Molecular BioSystems · doi:10.1039/c1mb05350g · Cited by 639
bioinformatics tools for mass spectroscopy-based metabolomic data processing and analysis
Sugimoto, M., Kawakami, M., Robert, M., Soga, T., & Tomita, M. (2012) · Current Bioinformatics · doi:10.2174/157489312799304431 · Cited by 307
“Even with the same algorithm, the use of different parameters strongly affected peak detection performance [58].”
MethodInfluentialMetabolomic Data Processing, Analysis, and Interpretation Using MetaboAnalyst
Xia, J., & Wishart, D. S. (2011) · Current Protocols in Bioinformatics · doi:10.1002/0471250953.bi1410s34 · Cited by 288
Broeckling, C. D., Afsar, F. A., Neumann, S., Ben-Hur, A., & Prenni, J. E. (2014) · Analytical Chemistry · doi:10.1021/ac501530d · Cited by 262
Computational mass spectrometry for small molecules
Scheubert, K., Hufsky, F., & Böcker, S. (2013) · Journal of Cheminformatics · doi:10.1186/1758-2946-5-12 · Cited by 173
“Brodsky et al [251] presented a method for evaluating individual peaks in a LC-MS spectrum, based on replicate samples.”
MethodEvaluating and minimizing batch effects in metabolomics
Han, W., & Li, L. (2022) · Mass Spectrometry Reviews · doi:10.1002/mas.21672 · Cited by 105
Metadata
- Authors
- Brodsky, L., Moussaieff, A., Shahaf, N., Aharoni, A., & Rogachev, I.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-10-26
- Volume
- 82
- Issue
- 22
- Pages
- 9177-9187
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2100200067
- Cited by
- 69
- References
- 2
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.