The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Size-Selective Microcavity Array for Rapid and Efficient Detection of Circulating Tumor Cells
Abstract
Circulating tumor cells (CTCs) are tumor cells circulating in the peripheral blood of patients with metastatic cancer. Detection of CTCs has clinical significance in cancer therapy because it would enable earlier diagnosis of metastasis. In this research, a microfluidic device equipped with a size-selective microcavity array for highly efficient and rapid detection of tumor cells from whole blood was developed. The microcavity array can specifically separate tumor cells from whole blood on the basis of differences in the size and deformability between tumor and hematologic cells. Furthermore, the cells recovered on the microcavity array were continuously processed for image-based immunophenotypic analysis using a fluorescence microscope. Our device successfully detected approximately 97% of lung carcinoma NCI-H358 cells in 1 mL whole blood spiked with 10-100 NCI-H358 cells. In addition, breast, gastric, and colon tumor cells lines that include EpCAM-negative tumor cells, which cannot be isolated by conventional immunomagnetic separation, were successfully recovered on the microcavity array with high efficiency (more than 80%). On an average, approximately 98% of recovered cells were viable. Our microfluidic device has high potential as a tool for the rapid detection of CTCs and can be used to study CTCs in detail.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Allard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Detection of Mutations in EGFR in Circulating Lung-Cancer Cells
Maheswaran, S., Sequist, L. V., Nagrath, S., Ulkus, L., Brannigan, B., Collura, C. V., Inserra, E., Diederichs, S., Iafrate, A. J., Bell, D. W., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800668 · Cited by 1,617
Shear-dependent deformation of erythrocytes in rheology of human blood
Chien, S., Usami, S., Dellenback, R., & Gregersen, M. (1970) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1970.219.1.136 · Cited by 201
Cited by
Current detection technologies for circulating tumor cells
Shen, Z., Wu, A., & Chen, X. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00803h · Cited by 433
Kelley, S. O., Mirkin, C. A., Walt, D. R., Ismagilov, R. F., Toner, M., & Sargent, E. H. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.261 · Cited by 398
Technologies for circulating tumor cell separation from whole blood
Bankó, P., Lee, S. Y., Nagygyörgy, V., Zrínyi, M., Chae, C. H., Cho, D. H., & Telekes, A. (2019) · Journal of Hematology & Oncology · doi:10.1186/s13045-019-0735-4 · Cited by 358
Sun, N., Li, X., Wang, Z., Li, Y., & Pei, R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.026 · Cited by 89
Recent advances in microfluidic methods in cancer liquid biopsy
Iliescu, F. S., Poenar, D. P., Yu, F., Ni, M., Chan, K. H., Cima, I., Taylor, H. K., Cima, I., & Iliescu, C. (2019) · Biomicrofluidics · doi:10.1063/1.5087690 · Cited by 51
Metadata
- Authors
- Hosokawa, M., Hayata, T., Fukuda, Y., Arakaki, A., Yoshino, T., Tanaka, T., & Matsunaga, T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-06-28
- Volume
- 82
- Issue
- 15
- Pages
- 6629-6635
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1984633251
- Cited by
- 344
- References
- 3
- FWCI
- 14.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.