CoChat

Improved Precision of iTRAQ and TMT Quantification by an Axial Extraction Field in an Orbitrap HCD Cell

Open access
Pichler, Peter, Köcher, Thomas, Holzmann, Johann, Möhring, Thomas, Ammerer, Gustav, Mechtler, Karl · 2011 · Analytical Chemistry
Cited by 55

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Improving analytical precision is a major goal in quantitative differential proteomics as high precision ensures low numbers of outliers, a source of false positives with regard to quantification. In addition, higher precision increases statistical power, i.e., the probability to detect significant differences. With chemical labeling using isobaric tags for relative and absolute quantitation (iTRAQ) or tandem mass tag (TMT) reagents, quantification is based on the extraction of reporter ions from tandem mass spectrometry (MS/MS) spectra. We compared the performance of two versions of the LTQ Orbitrap higher energy collisional dissociation (HCD) cell with and without an axial electric field with regard to reporter ion quantification. The HCD cell with the axial electric field was designed to push fragment ions into the C-trap and this version is mounted in current Orbitrap XL ETD and Orbitrap Velos instruments. Our goal was to evaluate whether the purported improvement in ion transmission had a measurable impact on the precision of MS/MS based quantification using peptide labeling with isobaric tags. We show that the axial electric field led to an increased percentage of HCD spectra in which the complete set of reporter ions was detected and, even more important, to a reduction in overall variance, i.e., improved analytical precision of the acquired data. Notably, adequate precision of HCD-based quantification was maintained even for low precursor ion intensities of a complex biological sample. These findings may help researchers in their design of quantitative proteomics studies using isobaric tags and establish HCD-based quantification on the LTQ Orbitrap as a highly precise approach in quantitative proteomics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac102265w

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 55

Metadata

Authors
Pichler, P., Köcher, T., Holzmann, J., Möhring, T., Ammerer, G., & Mechtler, K.
Venue
Analytical Chemistry
Published
2011-01-28
Volume
83
Issue
4
Pages
1469-1474
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2043594346
Cited by
55
References
4
FWCI
4.51
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved Precision of iTRAQ and TMT Quantification by an Axial Extraction Field in an Orbitrap HCD Cell. https://app.cochat.ai/papers/10.1021/ac102265w
The paper
Pichler, P., Köcher, T., Holzmann, J., Möhring, T., Ammerer, G., & Mechtler, K. (2011). Improved Precision of iTRAQ and TMT Quantification by an Axial Extraction Field in an Orbitrap HCD Cell. Analytical Chemistry. https://doi.org/10.1021/ac102265w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.