CoChat

Evaluation of Digital PCR for Absolute DNA Quantification

Sanders, Rebecca, Huggett, Jim F., Bushell, Claire A., Cowen, Simon, Scott, Daniel J., Foy, Carole A. · 2011 · Analytical Chemistry

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

The emerging technique of microfluidic digital PCR (dPCR) offers a unique approach to real-time quantitative PCR for measuring nucleic acids that may be particularly suited for low-level detection. In this study, we evaluated the quantitative capabilities of dPCR when measuring small amounts (<200 copies) of DNA and investigated parameters influencing technical performance. We used various DNA templates, matrixes, and assays to evaluate the precision, sensitivity and reproducibility of dPCR, and demonstrate that this technique can be highly reproducible when performed at different times and when different primer sets are targeting the same molecule. dPCR exhibited good analytical sensitivity and was reproducible outside the range recommended by the instrument manufacturer; detecting 16 estimated targets with high precision. The inclusion of carrier had no effect on this estimated quantity, but did improve measurement precision. We report disagreement when using dPCR to measure different template types and when comparing the estimated quantities by dPCR and UV spectrophotometry. Finally, we also demonstrate that preamplification can impose a significant measurement bias. These findings provide an independent assessment of low copy molecular measurement using dPCR and underline important factors for consideration in dPCR experimental design.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac103230c

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 32 references

Research works printed but not linked: 1

  1. Shih I. M., 2001, Cancer Res., 61, 818

Cited by

Items 101–200 of 370

Metadata

Authors
Sanders, R., Huggett, J. F., Bushell, C. A., Cowen, S., Scott, D. J., & Foy, C. A.
Affiliations
LGC (GB)
Corresponding author
Huggett, Jim F.
Venue
Analytical Chemistry
Published
2011-08-01
Volume
83
Issue
17
Pages
6474-6484
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1973214096
Cited by
338
References
32
Citations by year
2026: 9 · 2025: 20 · 2024: 11 · 2023: 29 · 2022: 26 · 2021: 26 · 2020: 31 · 2019: 29 · 2018: 23 · 2017: 17 · 2016: 36 · 2015: 25 · 2014: 24 · 2013: 19 · 2012: 10
FWCI
7.13
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
Keywords
digital PCR, microfluidic PCR, analytical sensitivity, measurement precision, reproducibility, primer sets, experimental design
MeSH terms
Alcohol Dehydrogenase, DNA, Spectrophotometry, Ultraviolet, Fusion Proteins, bcr-abl, Arabidopsis Proteins, Microfluidic Analytical Techniques, Real-Time Polymerase Chain Reaction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.