Evaluation of Digital PCR for Absolute DNA Quantification
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
The emerging technique of microfluidic digital PCR (dPCR) offers a unique approach to real-time quantitative PCR for measuring nucleic acids that may be particularly suited for low-level detection. In this study, we evaluated the quantitative capabilities of dPCR when measuring small amounts (<200 copies) of DNA and investigated parameters influencing technical performance. We used various DNA templates, matrixes, and assays to evaluate the precision, sensitivity and reproducibility of dPCR, and demonstrate that this technique can be highly reproducible when performed at different times and when different primer sets are targeting the same molecule. dPCR exhibited good analytical sensitivity and was reproducible outside the range recommended by the instrument manufacturer; detecting 16 estimated targets with high precision. The inclusion of carrier had no effect on this estimated quantity, but did improve measurement precision. We report disagreement when using dPCR to measure different template types and when comparing the estimated quantities by dPCR and UV spectrophotometry. Finally, we also demonstrate that preamplification can impose a significant measurement bias. These findings provide an independent assessment of low copy molecular measurement using dPCR and underline important factors for consideration in dPCR experimental design.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“dPCR is notably less variable between experiments (28,29)”
From Comparison of microfluidic digital PCR and conventional quantitative PCR for measuring copy number variation (2012) · cites this paper as [29]
In the citing paper
“However, such a step requires careful validation because of the potential bias that can be introduced that may outweigh the necessary precision for detecting small CNVs (29).”
From Comparison of microfluidic digital PCR and conventional quantitative PCR for measuring copy number variation (2012) · cites this paper as [29]
Citations
Cites
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
Self-citationVogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Gabert, J., Beillard, E., van der Velden, V. H. J., Bi, W., Grimwade, D., Pallisgaard, N., Barbany, G., Cazzaniga, G., Cayuela, J. M., Cavé, H., et al. (2003) · Leukemia · doi:10.1038/sj.leu.2403135 · Cited by 1,284
Beillard, E., Pallisgaard, N., van der Velden, V. H. J., Bi, W., Dee, R., van der Schoot, E., Delabesse, E., Macintyre, E., Gottardi, E., Saglio, G., et al. (2003) · Leukemia · doi:10.1038/sj.leu.2403136 · Cited by 881
Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria
Ottesen, E. A., Hong, J. W., Quake, S. R., & Leadbetter, J. R. (2006) · Science · doi:10.1126/science.1131370 · Cited by 737
Digital PCR for the molecular detection of fetal chromosomal aneuploidy
Lo, Y. M. D., Lun, F. M. F., Chan, K. C. A., Tsui, N. B. Y., Chong, K. C., Lau, T. K., Leung, T. Y., Zee, B. C. Y., Cantor, C. R., & Chiu, R. W. K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0705765104 · Cited by 434
Evidence that genetic instability occurs at an early stage of colorectal tumorigenesis.
Shih, I., Zhou, W. J., Goodman, S. N., Lengauer, C., Kinzler, K. W., & Vogelstein, B. (2001) · PubMed · Cited by 385
Transcription factor profiling in individual hematopoietic progenitors by digital RT-PCR
Warren, L., Bryder, D., Weissman, I. L., & Quake, S. R. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608512103 · Cited by 369
Diverse Tumorigenic Pathways in Ovarian Serous Carcinoma
Singer, G., Kurman, R. J., Chang, H.-W., Cho, S. K. R., & Shih, I.-M. (2002) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)62549-7 · Cited by 340
Dube, S., Qin, J., & Ramakrishnan, R. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002876 · Cited by 302
Research works printed but not linked: 1
- Shih I. M., 2001, Cancer Res., 61, 818
Cited by
Items 201–300 of 370
Droplet Digital PCR for Absolute Quantification of Plant Pathogens
Selvaraj, V., Maheshwari, Y., Hajeri, S., & Yokomi, R. K. (2019) · Springer eBooks · doi:10.1007/978-981-13-8499-8_25 · Cited by 11
Sanchez, M. E. N., Devard, N., Houy, C., Abachin, É., Godard, S., Esson, R., Chareyre, A., & Nougarede, N. (2020) · Biologicals · doi:10.1016/j.biologicals.2020.06.001 · Cited by 11
Design of a Digital LAMP Detection Platform Based on Droplet Microfluidic Technology
Jiang, L., Lan, X., Ren, L., Yang, M., Wei, B., & Wang, Y. (2023) · Micromachines · doi:10.3390/mi14051077 · Cited by 10
“To achieve higher sensitivity, a digital loop-mediated isothermal amplification (digital-LAMP) [12,13] has been developed, which was expected to achieve higher precision, higher sensitivity, and absolute quantitative analysis of test samples.”
Digital PCR as a Highly Sensitive Diagnostic Tool: a Review
Kopylova, K. V., Kasparov, E. W., Marchenko, I. V., & Smolnikova, M. V. (2023) · Molecular Biology · doi:10.31857/s0026898423050051 · Cited by 10
Heuverswyn, F. V., Karczmarczyk, M., Schimmel, H. G., Trapmann, S., & Emons, H. (2016) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2016.08.003 · Cited by 10
Guernic, A. L., Geffard, A., Rioult, D., Bigot‐Clivot, A., Leprêtre, M., & Ladeiro, M. P. (2020) · Fish & Shellfish Immunology · doi:10.1016/j.fsi.2020.10.027 · Cited by 10
Methods for Multiplex Template Sampling in Digital PCR Assays
Petriv, O. I., Heyries, K. A., VanInsberghe, M. A., Walker, D. C., & Hansen, C. L. (2014) · PLoS ONE · doi:10.1371/journal.pone.0098341 · Cited by 10
“The recent availability of dPCR instrumentation, including droplet formats and microfluidic formats [2,3,4,5,6,7], has made this method broadly available and has opened new opportunities in basic and clinical research.”
BackgroundResearch highlights: digital assays on chip
Kim, D., Wei, Q., Kong, J. E., Özcan, A., & Carlo, D. D. (2014) · Lab on a Chip · doi:10.1039/c4lc90119c · Cited by 10
Digital PCR and Its Potential Application to Microbiology
(2016) · Molecular Microbiology · doi:10.1128/9781555819071.ch4 · Cited by 10
Köppel, R., Bucher, T., Bär, D., van Velsen, F., & Ganeshan, A. (2017) · European Food Research and Technology · doi:10.1007/s00217-017-2957-4 · Cited by 10
Hayden, R. T. (2022) · Journal of Clinical Microbiology · doi:10.1128/jcm.01338-22 · Cited by 10
Elster, C., Klauenberg, K., Bär, M., Allard, A., Fischer, N., Kok, G., van der Veen, A. M. H., Harris, P. M., Cox, M. G., Smith, I., et al. (2013) · International Congress of Metrology (CIM) · doi:10.1051/metrology/201304003 · Cited by 9
Self-citationDeng, L., Yang, X., Xu, Z., Li, F., Zhao, J., Deng, H., Jian, Z., Sun, X., & Zhu, L. (2022) · Brazilian Journal of Microbiology · doi:10.1007/s42770-022-00728-y · Cited by 9
A Poisson-Independent Approach to Precision Nucleic Acid Quantification in Microdroplets
Ganguly, R., & Lee, C. (2024) · ACS Applied Bio Materials · doi:10.1021/acsabm.4c00350 · Cited by 9
Coyne, K. J., Wang, Y., Wood, S. A., Countway, P. D., & Greenlee, S. M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822861-6.00019-4 · Cited by 9
Baettig, C. G., Zirngibl, M., Smith, K. F., Lear, G., & Tremblay, L. A. (2023) · Marine Pollution Bulletin · doi:10.1016/j.marpolbul.2023.114829 · Cited by 9
Chen, N., & Schrijver, I. (2011) · Genetics in Medicine · doi:10.1097/gim.0b013e3182272e0b · Cited by 9
Evaluation of digital real-time PCR assay as a molecular diagnostic tool for single-cell analysis
Chang, C.-H., Mau‐Hsu, D., Chen, K.-C., Wei, C., Chiu, C.-Y., & Young, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-21041-5 · Cited by 9
Extraction-Free Absolute Quantification of Circulating miRNAs by Chip-Based Digital PCR
D’Alessandra, Y., Valerio, V., Moschetta, D., Massaiu, I., Bozzi, M., Conte, M., Parisi, V., Ciccarelli, M., Leosco, D., Myasoedova, V. A., et al. (2022) · Biomedicines · doi:10.3390/biomedicines10061354 · Cited by 9
“After PCR, each partition is analyzed for amplicon presence/absence, and the number of molecules in each reaction is estimated by applying the Poisson distribution [8].”
MethodXia, Y., Chu, X., Zhao, C., Wang, N., Yu, J., Jin, Y., Sun, L., & Ma, S. (2022) · Micromachines · doi:10.3390/mi13101667 · Cited by 9
A novel droplet digital PCR method for assessing the quantity and quality of degraded samples
Fu, X., Wang, Y., Liu, L., Xie, Q., Zheng, F., Wen, D., Xie, M., & Li, J. (2025) · Forensic Science International · doi:10.1016/j.forsciint.2025.112718 · Cited by 8
Nesvadbová, M., Dziedzinská, R., Hulánková, R., Babák, V., & Králík, P. (2023) · Food Control · doi:10.1016/j.foodcont.2023.110024 · Cited by 8
Pourghasemian, M. H., Barzoki, A. K., Dizani, M., Ashkezari, A. H. K., & Shamloo, A. (2025) · Sensors and Actuators Reports · doi:10.1016/j.snr.2025.100327 · Cited by 8
Mojtahedi, M., d’Hérouël, A. F., & Huang, S. (2014) · Nucleic Acids Research · doi:10.1093/nar/gku603 · Cited by 8
“In this situation, a fit of the empirical distribution from few observed positive events is futile, and straightforward counting of positive reactions is preferable in such a ‘low concentration’ regime (12).”
BackgroundInfluentialConvenient microfluidic cartridge for single-molecule droplet PCR using common laboratory equipment
Takahara, H., Matsushita, H., Inui, E., Ochiai, M., & Hashimoto, M. (2021) · Analytical Methods · doi:10.1039/d0ay01779e · Cited by 8
Poelvoorde, L. A. E. V., Dufrasne, F. E., Gucht, S. V., Saelens, X., & Roosens, N. H. C. (2023) · Current Issues in Molecular Biology · doi:10.3390/cimb45030165 · Cited by 8
Ding, R., Liu, L., Zhang, J., Lv, P., Zhou, L., Zhang, T., Li, S., Zhao, R., Yang, Z. Y., Xiong, P., et al. (2023) · Nucleic Acids Research · doi:10.1093/nar/gkad388 · Cited by 8
Accuracy of quantitative viral secondary standards: a re-examination
Hayden, R. T., Su, Y., Tang, L., Zhu, H., Gu, Z., Glasgow, H. L., Sam, S. S., & Caliendo, A. M. (2024) · Journal of Clinical Microbiology · doi:10.1128/jcm.01669-23 · Cited by 8
“…a potential for initial value assignment, for normalization of secondary standards to IU, and for lot-to-lot normalization of primary standards (13–15). dPCR was advocated for its use in our prior work to improve the accuracy of secondary standards, and the present study indicates that the…”
MethodWhitlam, J. B., Ling, L., Swain, M. I., Harrington, T., Mirochnik, O., Brooks, I., Cronin, S., Challis, J., Petrovic, V., Bruno, D. L., et al. (2017) · Experimental Hematology · doi:10.1016/j.exphem.2017.01.004 · Cited by 8
Detection of microRNAs Using Chip-Based QuantStudio 3D Digital PCR
Borzi, C., Calzolari, L., Conte, D., Sozzi, G., & Fortunato, O. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-6866-4_16 · Cited by 8
Whale, A. S., Fernández-González, A., Gutteridge, A., & Devonshire, A. S. (2018) · Methods in molecular biology · doi:10.1007/978-1-4939-7778-9_4 · Cited by 8
Li, L., Zhang, X., Wan, Y., & Jin, W. (2013) · BioMed Research International · doi:10.1155/2013/134675 · Cited by 8
“Hindawi Publishing Corporation BioMed Research International Volume 2013, Article ID 134675, 7 pages http://dx.doi.org/10.1155/2013/134675”
InfluentialYoo, H.-B., Oh, D., Song, J. Y., Kawaharasaki, M., Hwang, J., Yang, I. C., & Park, S.-R. (2014) · Metrologia · doi:10.1088/0026-1394/51/5/491 · Cited by 8
One Assay, Nine Targets: Advancing Viral Surveillance with Multiplex RT-ddPCR
Zafeiriadou, A., Georgakopoulou, G., Pitaouli, F., Τhomaidis, Ν. S., & Markou, A. N. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c04372 · Cited by 7
Gu, Z., Chen, L., Zhang, W., Su, P., Zhang, D., Du, X., Peng, Q., Liu, Z., Liao, X., & Liu, Y. (2023) · Canadian Journal of Infectious Diseases and Medical Microbiology · doi:10.1155/2023/9933783 · Cited by 7
“Since the invention of real-time PCR, this technology has been widely applied to molecular biology studies [28].”
Yadav, A. S., Galogahi, F. M., Tran, D. T., Vashi, A. V., Ooi, C. H., Sreejith, K. R., & Nguyen, N. (2023) · Lab on a Chip · doi:10.1039/d3lc00337j · Cited by 7
Diagnosis of Aquatic Animal Viral Diseases
Kibenge, F. S. B., Godoy, M., & Kibenge, M. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-801573-5.00004-8 · Cited by 7
Tanvetthayanont, P., Yata, T., Boonnil, J., Temisak, S., & Ponglowhapan, S. (2022) · Scientific Reports · doi:10.1038/s41598-022-17493-5 · Cited by 7
Extending digital PCR analysis by modelling quantification cycle data
Wilson, P. J., & Ellison, S. L. R. (2016) · BMC Bioinformatics · doi:10.1186/s12859-016-1275-3 · Cited by 7
“…Chain Reaction (dPCR) is a technique first published in [1] that is used to quantify deoxyribonucleic acid (DNA) and other nucleic acids such as ribo-nucleic acid (RNA) for a variety of applications such as absolute quantification [2], copy number variation [3] and rare mutation detection [4].”
MethodDeveloping centrifugal force real-time digital PCR for detecting extremely low DNA concentration
Shin, J. C., Jeong, J.-Y., Son, S. G., Choi, S.-H., Nam, H. C., Yoon, T.-H., Kim, H.-J., Choi, D.-G., Lee, H., Lee, U., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-62199-5 · Cited by 6
Ramos, K. C., Trejo, F., Salas-Navarrete, P. C., Ramón‐Gallegos, E., Muñoz‐Medina, J. E., Álvarez-Icaza, L. A., Olguín, L. F., Pilloni, O., & Oropeza-Ramos, L. A. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-00982-8 · Cited by 6
Abousenna, M. S. (2026) · Veterinary Immunology and Immunopathology · doi:10.1016/j.vetimm.2026.111109 · Cited by 6
Shibayama, S., Fujii, S., Inagaki, K., Yamazaki, T., Yoshioka, M., Matsukura, S., Sasaki, A., Suyama, T., Noda, N., Sekiguchi, Y., et al. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01992-y · Cited by 6
Using genomic DNA copies to enumerate Mycobacterium tuberculosis load in macaque tissue samples
Willemse, D., & Kaushal, D. (2021) · Tuberculosis · doi:10.1016/j.tube.2021.102102 · Cited by 6
Yao, B., Sun, D., Ren, Y., & Wang, M. (2022) · Journal of Chemical Education · doi:10.1021/acs.jchemed.1c00530 · Cited by 6
Shah, P. S., Murarka, S. M., Joshi, A., Mehta, B. A., Parmar, V. H., Shah, N. D., Patel, K., & Sands, J. M. (2018) · Breast Cancer Targets and Therapy · doi:10.2147/bctt.s161264 · Cited by 6
“12 In addition to this, the inherent dilution of samples in dPCR enables significant dilution of inhibitors.”
High-yield extraction of Escherichia coli RNA from human whole blood
Brennecke, J., Kraut, S., Zwadlo, K., Gandi, S. K., Pritchard, D., Templeton, K. E., & Bachmann, T. T. (2017) · Journal of Medical Microbiology · doi:10.1099/jmm.0.000439 · Cited by 6
“[66, 67] Consequently, the direct addition of RNAprotect without prior lysis of the blood cells gave the best results for low numbers of bacterial cells with respect to signal intensity.”
BackgroundSheng, N., Zou, B., Tong, H., Lu, Y. Z., Xing, S., Song, Q., & Zhou, G. (2019) · The Analyst · doi:10.1039/c9an00970a · Cited by 6
Molecular Biology and Biotechnology
(2021) · Royal Society of Chemistry eBooks · doi:10.1039/9781839168963 · Cited by 6
Integration of wide-field imaging system with droplet microfluidics for monitoring living bacteria
Ki, S., Shin, H., & Kang, D. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.135765 · Cited by 5
Influence of microfabrication on digital PCR performance in bead-based microwell array assays
Riley, B. F. M., Ward, C. L., & Linz, T. H. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02822-2 · Cited by 5
Munna, M. S. A., Islam, M. M., Rabbi, M. A., Mefford, O. T., Malaj, A., Islam, M. S., Ahmad, H., & Rahman, M. M. (2025) · RSC Advances · doi:10.1039/d5ra04563k · Cited by 4
“35 Therefore, an alternative method for easy, fast and precise detection and quanti cation of DNA is required to address the current limitations.”
Basic Molecular Biology Techniques
Rapley, R. (2021) · Royal Society of Chemistry eBooks · doi:10.1039/9781788017862-00001 · Cited by 4
Sessions, A. L., Magnabosco, C., Barton, H. A., Burkhardt, C., Dworkin, J. P., Freissinet, C., French, K. L., GLAVIN, D. P., Leys, N., Maixner, F., et al. (2025) · Astrobiology · doi:10.1177/15311074251382157 · Cited by 4
“Such techniques are well developed and can be adapted to target both intracellular and extracellular DNA pools (Guo and Zhang, 2013; Lever et al., 2015; Sanders et al., 2011).”
Miyata, M., Yoshida, J., Takagishi, I., & Horie, K. (2022) · DNA Research · doi:10.1093/dnares/dsac045 · Cited by 4
Vibrio-Sequins - dPCR-traceable DNA standards for quantitative genomics of Vibrio spp
Flütsch, S., Wiestner, F., Butticaz, L., Moor, D., & Stölting, K. N. (2023) · BMC Genomics · doi:10.1186/s12864-023-09429-8 · Cited by 4
Hafzari, R., Annisa, A., Kairani, A., Cholis, M. N., Kirana, L. P., Panggabean, N. H., Situmorang, N., & Marpaung, D. R. A. K. (2024) · Journal of Microbiology Biotechnology and Food Sciences · doi:10.55251/jmbfs.10691 · Cited by 4
Applications of Digital PCR in Clinical Microbiology
Brazelton, J. N., & Hayden, R. T. (2018) · Springer eBooks · doi:10.1007/978-3-319-95111-9_29 · Cited by 4
Farr, R. J., Wong, W. K. M., Maynard, C.-L., Tersey, S. A., Mirmira, R. G., Hardikar, A. A., & Joglekar, M. V. (2019) · Journal of Biological Methods · doi:10.14440/jbm.2019.280 · Cited by 4
“dPCR is becoming an increasingly popular method of quantifying nucleic acids as it is able to provide absolute quantitation of target gene/transcript copies, thereby offering a more sensitive and absolutely quantifiable technology than conventional real-time qPCR and other existing technologies [11-14].”
MethodMaynard, C.-L., Wong, W. K. M., Hardikar, A. A., & Joglekar, M. V. (2019) · Methods in molecular biology · doi:10.1007/978-1-4939-9631-5_4 · Cited by 4
Zea maize reference materials for genetically modified organism detection in Mexico
Galván, E. C., Torres, M. M., & Urquiza, M. P. (2019) · Ecology and Evolution · doi:10.1002/ece3.5667 · Cited by 4
“The equipment with the technology of droplet digital coupled with polymerase chain reaction (ddPCR) is considered a primary method, because it is capable of producing an absolute measurement (Félix‐Urquídez et al., 2015; Pérez‐Urquiza & Acatzi, 2014; Rebecca et al., 2011).”
MethodCalabrese, S., Markl, A. M., Neugebauer, M., Krauth, S. J., Borst, N., von Stetten, F., & Lehnert, M. (2023) · The Analyst · doi:10.1039/d3an00191a · Cited by 4
Determination of HSV-1 UL5 and UL29 gene copy numbers in an HSV complementing Vero cell line
Azizi, A., Aidoo, F., Gisonni-Lex, L., & McNeil, B. (2013) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2013.10.002 · Cited by 4
Jue, E., & Ismagilov, R. F. (2020) · medRxiv · doi:10.1101/2020.04.28.20077602 · Cited by 4
“In this manuscript, we aimed to resolve the discrepancies in the LODs obtained with the three SARS‐CoV‐ 2 NA stocks by performing our own quantification of each stock concentration using a highly sensitive digital quantification method, reverse transcription digital PCR (RT‐dPCR).[6, 7]”
MethodLee, S. J., Lee, J., Ahn, A., Lee, S., Hong, Y., Lee, D., Song, H., Song, M., Shin, S., Kim, M., et al. (2024) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.25034 · Cited by 3
Maeda, C., Yusuke, O. N. O., TAKAHASHI, K., Mori, M., Suzuki, M., Tamamura, N., Sun, Y., Itoh, T., Tanaka, H., Kawabata, H., et al. (2025) · Clinical Chemistry · doi:10.1093/clinchem/hvaf181 · Cited by 3
Shen, J., Fan, J., Xu, G., Zhao, Z., Li, H., & Wu, D. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118952 · Cited by 3
Progress of Digital PCR for Single DNA Quantification*
Li, L., Sui, Z., Jing, W. A. N. G., Zang, C., & Yu, X. (2012) · PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS · doi:10.3724/sp.j.1206.2012.00003 · Cited by 3
Digital detection of T790M—yes or no to an ultrasensitive assay
Wang, W., Karampini, E., Correia, L. L., & McCaughan, F. M. (2016) · Translational Lung Cancer Research · doi:10.21037/tlcr.2016.05.01 · Cited by 3
A Developed Accurate Digital PCR Detection Technology in Food Safety
Xu, W. (2016) · Springer eBooks · doi:10.1007/978-981-10-1618-9_7 · Cited by 3
Foodomics evaluation of genetically modified organisms
León, C., & Cifuentes, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-813266-1.00015-2 · Cited by 3
Brandsegg, H. (2015) · BIBSYS Brage (BIBSYS (Norway)) · Cited by 3
Improving Specificity of Cerebrospinal Fluid Liquid Biopsy for Genetic Testing
Ye, Z., Scheffer, I. E., Berkovic, S. F., & Hildebrand, M. S. (2021) · Annals of Neurology · doi:10.1002/ana.26191 · Cited by 3
Fast Thermocycling in Custom Microfluidic Cartridge for Rapid Single-Molecule Droplet PCR
Takahara, H., Tanaka, H., & Hashimoto, M. (2023) · Sensors · doi:10.3390/s23249884 · Cited by 2
Wu, R. P., Luh, F., Kweon, S.-M., & Yen, Y. (2025) · Molecular Therapy — Methods & Clinical Development · doi:10.1016/j.omtm.2025.101483 · Cited by 2
“4 One limitation to quantifying the sample concentrations in dPCR reactions is the requirement of knowing the exact volume of partition.”
Whale, A. S., O’Sullivan, D. M., & Huggett, J. F. (2025) · Wiley eBooks · doi:10.1002/9781683674597.ch2 · Cited by 2
Self-citationFan, J., Shen, J., Zhao, Z., Xu, G., & Wu, D. (2025) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2025.138123 · Cited by 2
Kurtz, P., Domingo, J. W. S., Pyron, R. A., & Wendell, D. (2025) · PLoS ONE · doi:10.1371/journal.pone.0328633 · Cited by 2
“Notably, the 35 round HB503 enrichment produced a limit of detection an order of magnitude more sensitive at 5 copies/µL than that of either single primer set’s performance—demon-strating the nested method’s superior low-copy detection on eDNA samples (Fig 1A [65,66].”
Guo, Y., Li, K., Long, Y., Li, F., Li, F., Liu, Y., Zhou, J. Z., & Li, L. (2025) · Talanta · doi:10.1016/j.talanta.2025.128758 · Cited by 2
Zeng, W., Luo, W., Zhou, J., Wang, B., Qin, H., He, Y., Gablech, I., Korabečná, M., & Neužil, P. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118695 · Cited by 2
Digital microfluidics-engaged automated enzymatic degradation and synthesis of oligosaccharides
Sun, Y., Wu, Y., Ma, D., Li, J., Liu, X., You, Y., Lü, J., Liu, Z., Cheng, X., & Du, Y. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1201300 · Cited by 2
“DMF is being extensively used to miniaturize a wide range of biochemical applications, such as PCR (Sanders et al., 2011), single cell analysis and immunoassay (He et al.”
BackgroundMethodInfluentialTanvetthayanont, P., Yata, T., Boonnil, J., Temisak, S., & Ponglowhapan, S. (2024) · Theriogenology · doi:10.1016/j.theriogenology.2024.01.016 · Cited by 2
Droplet Gene Analysis – Digital PCR
Gegevicius, E., Goda, K., & Mažutis, L. (2020) · Royal Society of Chemistry eBooks · doi:10.1039/9781839162855-00089 · Cited by 2
The prevalence of selected emerging pathogenic species in wastewater and receiving water bodies
Govender, R. (2022) · DUT Open Scholar (Durban University of Technology) · doi:10.51415/10321/4110 · Cited by 2
Standardization and Comparison of Emergency Use Authorized COVID-19 Assays and Testing LaboratoriesPreprint
Rao, A., Lin, J., Parsons, R., Greenleaf, M. N., Westbrook, A. L., Lai, E., Bowers, H. B., McLendon, K. B., O’Sick, W., Baugh, T., et al. (2023) · medRxiv · doi:10.1101/2023.11.08.23297633 · Cited by 2
Nucleic Acid Structure and Basic Analysis
Rapley, R. (2019) · Royal Society of Chemistry eBooks · doi:10.1039/9781782628217-00001 · Cited by 1
Fish Traceability and Authenticity
Sotelo, C. G., Gunnlaugsson, V. N., Schröder, U. B., Mendes, R. O., van Kappel, K., Silva, H. A., & Verrez‐Bagnis, V. (2023) · Wiley eBooks · doi:10.1002/9781394264728.ch4 · Cited by 1
Diagnosis of aquatic animal viral diseases
Kibenge, F. S. B., Godoy, M., & Kibenge, M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-91169-6.00024-8 · Cited by 1
Moloney, G. K., Heighton, S. P., Parthuisot, N., Missoup, A. D., Momboua, B. R., Djagoun, C. A. M. S., Bi, S. G., Chaber, A., & Gaubert, P. (2025) · Forensic Science International Genetics · doi:10.1016/j.fsigen.2025.103366 · Cited by 1
Maretto, L., Deb, S., Squartini, A., Concheri, G., Stevanato, P., Nardi, S., Cocco, S., & Corti, G. (2025) · PLoS ONE · doi:10.1371/journal.pone.0336235 · Cited by 1
“The decision to employ dPCR, a robust molecular technique known for its high biological sensitivity and reproducibility [65], enables the detection of challenging DNA quantities without the need for an external calibration curve [66,67].”
Applications of digital polymerase chain reaction in environment and forensic chemistry
Etim, S., Raha, D., Duncan, G., & McCord, B. R. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-30128-5.00032-1 · Cited by 1
Development and Validation of a Droplet Digital PCR Assay for Detection of Feline Herpesvirus Type-1
Zhou, Y., Wu, D., Tang, M., Ye, Z., Feng, E., Zhang, H., Luo, G., Wang, Z., Wang, C., Liu, L., et al. (2025) · Veterinary Sciences · doi:10.3390/vetsci12111107 · Cited by 1
“Currently, dPCR is primarily applied for rare mutant genes detection [13,14], viral load quantification [15–17], and precise copy number quantification (CNV and NGS libraries) [18], etc.”
A State-of-the-Art Digital PCR Platform
Lebedeva, Y. L., Александрович, Ч. Е., & Акимкин, В. Г. (2025) · Applied Biochemistry and Microbiology · doi:10.1134/s0003683825700188 · Cited by 1
Tynan, K. J., Singh, K., Mouchahoir, T., Lowenthal, M. S., & Phinney, K. W. (2026) · Discover Pharmaceutical Sciences · doi:10.1007/s44395-026-00058-0 · Cited by 1
“Therefore, the choice of data analysis method should consider the target substance and available reference materials [44]. dPCR enables the absolute counting of target molecules by isolating them through limited dilution and partitioning prior to amplification via traditional PCR [45, 91, 92].”
White, R. A., III, Brazelton, J. N., & Hayden, R. T. (2015) · Methods in microbiology · doi:10.1016/bs.mim.2015.09.001 · Cited by 1
The genetics of chronic myelogenous leukaemia
May, P. C., Khorashad, J. S., Alikian, M., Perrotti, D., & Reid, A. G. (2016) · Wiley eBooks · doi:10.1002/9781118527948.ch7 · Cited by 1
Identification and Assessment of Heavy Metal Pollution Using Nucleic Acid-Mediated Technologies
Xu, W. (2016) · Springer eBooks · doi:10.1007/978-981-10-1618-9_17 · Cited by 1
Köppel, R., Peterseil, V., Dagand, E., Schütz, E., Kolberg, N., Milavec, M., & Moor, D. (2016) · European Food Research and Technology · doi:10.1007/s00217-016-2824-8 · Cited by 1
Linkage assay by digital droplet PCR to assess the freshness of orange juice
Köppel, R., van Velsen, F., & Ganeshan, A. (2016) · European Food Research and Technology · doi:10.1007/s00217-016-2818-6 · Cited by 1
Jearapong, N., & Jarukamjorn, K. (2013) · วารสารวิทยาศาสตร์และเทคโนโลยี มหาวิทยาลัยมหาสารคาม (Journal of Science and Technology Mahasarakham University) · Cited by 1
Metadata
- Authors
- Sanders, R., Huggett, J. F., Bushell, C. A., Cowen, S., Scott, D. J., & Foy, C. A.
- Affiliations
- LGC (GB)
- Corresponding author
- Huggett, Jim F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-08-01
- Volume
- 83
- Issue
- 17
- Pages
- 6474-6484
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1973214096
- Cited by
- 338
- References
- 32
- Citations by year
- 2026: 9 · 2025: 20 · 2024: 11 · 2023: 29 · 2022: 26 · 2021: 26 · 2020: 31 · 2019: 29 · 2018: 23 · 2017: 17 · 2016: 36 · 2015: 25 · 2014: 24 · 2013: 19 · 2012: 10
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- digital PCR, microfluidic PCR, analytical sensitivity, measurement precision, reproducibility, primer sets, experimental design
- MeSH terms
- Alcohol Dehydrogenase, DNA, Spectrophotometry, Ultraviolet, Fusion Proteins, bcr-abl, Arabidopsis Proteins, Microfluidic Analytical Techniques, Real-Time Polymerase Chain Reaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.