The DOI matches its Crossref record.
Magnetic Nanoparticle-Enhanced Biosensor Based on Grating-Coupled Surface Plasmon Resonance
Abstract
A highly sensitive surface plasmon resonance (SPR) biosensor employing magnetic nanoparticle (MNP) assays is presented. In the reported approach, MNPs simultaneously served as "vehicles" for rapid delivery of target analyte from a sample to the sensor surface and as labels increasing the measured refractive index changes that are associated with the binding of target analyte. An optical setup based on grating-coupled surface plasmon resonance (GC-SPR) was used with a magnetic field gradient applied through the sensor chip for manipulating with MNPs on its surface. Iron oxide MNPs and a sensor surface with metallic diffraction grating were modified with antibodies that specifically recognize different epitopes of the analyte of interest. The sensitivity of the biosensor was investigated as a function of mass transport of the analyte to the sensor surface driven by diffusion (free analyte) or by the magnetic field gradient (analyte bound to MNPs). Immunoassay-based detection of β human chorionic gonadotropin (βhCG) was implemented to evaluate the sensitivity of the MNP-enhanced GC-SPR biosensor scheme. The results reveal that the sensitivity of βhCG detection was improved by 4 orders of magnitude compared with the regular SPR sensor with direct detection format, and a limit of detection below pM was achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wu, W., Wu, Z., Yu, T., Jiang, C., & Kim, W.-S. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/2/023501 · Cited by 1,574
Nanomaterials enhanced surface plasmon resonance for biological and chemical sensing applications
Zeng, S., Baillargeat, D., Ho, H.-P., & Yong, K.-T. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60479a · Cited by 1,230
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Nanoparticle-Based Immunochemical Biosensors and Assays: Recent Advances and Challenges
Farka, Z., Juřík, T., Kovář, D., Trnková, L., & Skládal, P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00037 · Cited by 694
Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics
Masson, J.-F. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00763 · Cited by 663
Metadata
- Authors
- Wang, Y., Dostalek, J., & Knoll, W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-07-14
- Volume
- 83
- Issue
- 16
- Pages
- 6202-6207
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2316054110
- Cited by
- 176
- References
- 0
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Nanoparticle-Enhanced Biosensor Based on Grating-Coupled Surface Plasmon Resonance. https://app.cochat.ai/papers/10.1021/ac200751s
- The paper
- Wang, Y., Dostalek, J., & Knoll, W. (2011). Magnetic Nanoparticle-Enhanced Biosensor Based on Grating-Coupled Surface Plasmon Resonance. Analytical Chemistry. https://doi.org/10.1021/ac200751s
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.