Structural Analysis of Intact Monoclonal Antibodies by Electron Transfer Dissociation Mass Spectrometry
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Improving qualitative and quantitative characterization of monoclonal antibodies is essential, because of their increasing popularity as therapeutic drug targets. Electron transfer dissociation (ETD)-based top-down mass spectrometry (MS) is the method of choice for in-depth characterization of post-translationally modified large peptides, small- and medium-sized proteins, and noncovalent protein complexes. Here, we describe the performance of ETD-based top-down mass spectrometry for structural analysis of intact 150 kDa monoclonal antibodies, immunoglobulins G (IgGs). Simultaneous mass analysis of intact IgGs as well as a complex mixture of ETD product ions at sufficiently high resolution and mass accuracy in a wide m/z range became possible because of recent advances in state-of-the-art time-of-flight (TOF) mass spectrometry. High-resolution ETD TOF MS performed on IgG1-kappa from murine myeloma cells and human anti-Rhesus D IgG1 resulted in extensive sequence coverage of both light and heavy chains of IgGs and revealed information on their variable domains. Results are superior and complementary to those previously generated by collision-induced dissociation. However, numerous disulfide bonds drastically reduce the efficiency of top-down ETD fragmentation within the protected sequence regions, leaving glycosylation uncharacterized. Further increases in the experiment sensitivity and improvement of ion activation before and after ETD reaction are needed to target S-S bond-protected sequence regions and post-translational modifications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Decoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503
Zamdborg, L., LeDuc, R. D., Glowacz, K. J., Kim, Y.-B., Viswanathan, V., Spaulding, I. T., Early, B. P., Bluhm, E. J., Babai, S., & Kelleher, N. L. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm371 · Cited by 251
Ge, Y., Rybakova, I. N., Xu, Q., & Moss, R. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813369106 · Cited by 154
Cited by
Characterization of Therapeutic Antibodies and Related Products
Beck, A., Wagner-Rousset, E., Ayoub, D., Van Dorsselaer, A., & Sanglier-Cianférani, S. (2013) · Analytical Chemistry · doi:10.1021/ac3032355 · Cited by 587
Fornelli, L., Srzentić, K., Huguet, R., Mullen, C., Sharma, S., Zabrouskov, V., Fellers, R. T., Durbin, K. R., Compton, P. D., & Kelleher, N. L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00984 · Cited by 150
Self-citationRoberts, D. S., Loo, J. A., Tsybin, Y. O., Liu, X., Wu, S., Chamot-Rooke, J., Agar, J. N., Paša-Tolić, L., Smith, L. M., & Ge, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00318-2 · Cited by 161
Self-citationShaw, J. B., Liu, W., Vasil′ev, Y. V., Bracken, C. C., Malhan, N., Guthals, A., Beckman, J. S., & Voinov, V. G. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03129 · Cited by 77
Jin, Y., Lin, Z., Xu, Q., Fu, C., Zhang, Z., Zhang, Q., Pritts, W. A., & Ge, Y. (2019) · mAbs · doi:10.1080/19420862.2018.1525253 · Cited by 68
Metadata
- Authors
- Tsybin, Y. O., Fornelli, L., Stoermer, C., Luebeck, M., Parra, J., Nallet, S., Wurm, F. M., & Hartmer, R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-11-04
- Volume
- 83
- Issue
- 23
- Pages
- 8919-8927
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2007167393
- Cited by
- 138
- References
- 5
- FWCI
- 6.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.