The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Aptamer Biosensor Based on Fluorescence Resonance Energy Transfer from Upconverting Phosphors to Carbon Nanoparticles for Thrombin Detection in Human Plasma
Abstract
We presented a new aptamer biosensor for thrombin in this work, which was based on fluorescence resonance energy transfer (FRET) from upconverting phosphors (UCPs) to carbon nanoparticles (CNPs). The poly(acrylic acid) (PAA) functionalized UCPs were covalently tagged with a thrombin aptamer (5'-NH(2)- GGTTGGTGTGGTTGG-3'), which bound to the surface of CNPs through π-π stacking interaction. As a result, the energy donor and acceptor were taken into close proximity, leading to the quenching of fluorescence of UCPs. A maximum fluorescence quenching rate of 89% was acquired under optimized conditions. In the presence of thrombin, which induced the aptamer to form quadruplex structure, the π-π interaction was weakened, and thus, the acceptor was separated from the donor blocking the FRET process. The fluorescence of UCPs was therefore restored in a thrombin concentration-dependent manner, which built the foundation of thrombin quantification. The sensor provided a linear range from 0.5 to 20 nM for thrombin with a detection limit of 0.18 nM in an aqueous buffer. The same linear range was obtained in spiked human serum samples with a slightly higher detection limit (0.25 nM), demonstrating high robustness of the sensor in a complex biological sample matrix. As a practical application, the sensor was used to monitor thrombin level in human plasma with satisfactory results obtained. This is the first time that UCPs and CNPs were employed as a donor-acceptor pair to construct FRET-based biosensors, which utilized both the photophysical merits of UCPs and the superquenching ability of CNPs and thus afforded favorable analytical performances. This work also opened the opportunity to develop biosensors for other targets using this UCPs-CNPs system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Luminescent Carbon Nanodots: Emergent Nanolights
Baker, S. N., & Baker, G. A. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906623 · Cited by 4,921
DNA-assisted dispersion and separation of carbon nanotubes
Zheng, M., Jagota, A., Semke, E. D., Diner, B. A., Mclean, R. S., Lustig, S. R., Richardson, R. E., & Tassi, N. G. (2003) · Nature Materials · doi:10.1038/nmat877 · Cited by 2,699
A Graphene Platform for Sensing Biomolecules
Lu, C., Yang, H., Zhu, C., Chen, X., & Chen, G. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901479 · Cited by 2,051
Fluorescent Carbon Nanoparticles Derived from Candle Soot
Liu, H., Ye, T., & Mao, C. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200701271 · Cited by 1,688
Structure-Based Carbon Nanotube Sorting by Sequence-Dependent DNA Assembly
Zheng, M., Jagota, A., Strano, M. S., Santos, A. P., Barone, P., Chou, S. G., Diner, B. A., Dresselhaus, M. S., Mclean, R. S., Onoa, G. B., et al. (2003) · Science · doi:10.1126/science.1091911 · Cited by 1,594
Sapsford, K. E., Berti, L., & Medintz, I. L. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503873 · Cited by 1,561
Carbon Nanomaterials in Biosensors: Should You Use Nanotubes or Graphene?
Yang, W., Ratinac, K. R., Ringer, S. P., Thordarson, P., Gooding, J. J., & Braet, F. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903463 · Cited by 1,431
Hexagonal Sodium Yttrium Fluoride Based Green and Blue Emitting Upconversion Phosphors
Krämer, K. W., Biner, D., Frei, G., Güdel, H. U., Hehlen, M. P., & Lüthi, S. R. (2004) · Chemistry of Materials · doi:10.1021/cm031124o · Cited by 1,172
Fluorescence Resonant Energy Transfer Biosensor Based on Upconversion‐Luminescent Nanoparticles
Wang, L., Yan, R., Huo, Z., Wang, L., Zeng, J., Bao, J., Wang, X., Peng, Q., & Li, Y. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200501907 · Cited by 901
Graphene Fluorescence Resonance Energy Transfer Aptasensor for the Thrombin Detection
Chang, H., Tang, L., Wang, Y., Jiang, J., & Li, J. (2010) · Analytical Chemistry · doi:10.1021/ac9025384 · Cited by 892
Self-citationChen, Z., Chen, H., Hu, H., Yu, M., Li, F., Zhang, Q., Zhou, Z., Yi, T., & Huang, C. (2008) · Journal of the American Chemical Society · doi:10.1021/ja076151k · Cited by 836
Electronic Aptamer‐Based Sensors
Willner, I., & Zayats, M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604524 · Cited by 818
Photoinduced electron transfers with carbon dots
Wang, X., Cao, L., Lu, F., Meziani, M. J., Li, H., Qi, G., Zhou, B., Harruff, B. A., Kermarrec, F., & Sun, Y.-P. (2009) · Chemical Communications · doi:10.1039/b906252a · Cited by 814
Dong, H., Gao, W., Yan, F., Ji, H., & Ju, H. (2010) · Analytical Chemistry · doi:10.1021/ac100852z · Cited by 777
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Antigen/Antibody Immunocomplex from CdTe Nanoparticle Bioconjugates
Wang, S., Mamedova, N., Kotov, N. A., Chen, W., & Studer, J. (2002) · Nano Letters · doi:10.1021/nl0255193 · Cited by 529
CdSe−ZnS Quantum Dots as Resonance Energy Transfer Donors in a Model Protein−Protein Binding Assay
Willard, D. M., Carillo, L. L., Jung, J., & Van Orden, A. (2001) · Nano Letters · doi:10.1021/nl015565n · Cited by 493
Aptamer-Based Detection of Plasma Proteins by an Electrochemical Assay Coupled to Magnetic Beads
Centi, S., Tombelli, S., Minunni, M., & Mascini, M. (2007) · Analytical Chemistry · doi:10.1021/ac061879p · Cited by 409
Nucleic acid detection using carbon nanoparticles as a fluorescent sensing platform
Li, H., Zhang, Y., Wang, L., Tian, J., & Sun, X. (2011) · Chem. Commun. · doi:10.1039/c0cc04326e · Cited by 321
Cancer Cell Targeting Using Multiple Aptamers Conjugated on Nanorods
Huang, Y.-F., Chang, H.-T., & Tan, W. (2008) · Analytical Chemistry · doi:10.1021/ac702322j · Cited by 303
Zhang, C., Yuan, Y., Zhang, S., Wang, Y., & Liu, Z. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201100769 · Cited by 288
Self-citationA Graphene‐Based Platform for the Assay of Duplex‐DNA Unwinding by Helicase
Jang, H., Kim, Y., Kwon, H., Yeo, W., Kim, D., & Min, D. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201001332 · Cited by 241
Schmid, J. A., Scholze, P., Kudlacek, O., Freissmuth, M., Singer, E. A., & Sitte, H. H. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m007357200 · Cited by 216
Homogeneous Assay Technology Based on Upconverting Phosphors
Kuningas, K., Rantanen, T., Ukonaho, T., Lövgren, T. N.-E., & Soukka, T. (2005) · Analytical Chemistry · doi:10.1021/ac0510944 · Cited by 165
Upconversion Fluorescence Resonance Energy Transfer in a Homogeneous Immunoassay for Estradiol
Kuningas, K., Ukonaho, T., Päkkilä, H., Rantanen, T., Rosenberg, J., Lövgren, T. N.-E., & Soukka, T. (2006) · Analytical Chemistry · doi:10.1021/ac0603983 · Cited by 157
Hu, J., Zheng, P., Jiang, J., Shen, G., Yu, R., & Liu, G. (2008) · Analytical Chemistry · doi:10.1021/ac801431m · Cited by 130
Clapp, A. R., Pons, T., Medintz, I. L., Delehanty, J. B., Melinger, J. S., Tiefenbrunn, T. K., Dawson, P. E., Fisher, B. R., O'Rourke, B. P., & Mattoussi, H. M. (2007) · Advanced Materials · doi:10.1002/adma.200602036 · Cited by 123
Liu, M., Zhao, H., Quan, X., Chen, S., & Fan, X. (2010) · Chemical Communications · doi:10.1039/c0cc02085k · Cited by 110
A graphene oxide-based nano-beacon for DNA phosphorylation analysis
Wu, W., Hu, H., Fan, L., Wang, L., Gao, J., Lu, J., & Fan, C. (2010) · Chemical Communications · doi:10.1039/c0cc04312e · Cited by 102
Upconversion Fluorescence Enables Homogeneous Immunoassay in Whole Blood
Kuningas, K., Päkkilä, H., Ukonaho, T., Rantanen, T., Lövgren, T. N.-E., & Soukka, T. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.076687 · Cited by 89
Red Laser-Induced Fluorescence Energy Transfer in an Immunosystem
Oswald, B., Lehmann, F., Simon, L., Terpetschnig, E., & Wolfbeis, O. S. (2000) · Analytical Biochemistry · doi:10.1006/abio.2000.4553 · Cited by 64
Cited by
Carbon quantum dots: synthesis, properties and applications
Wang, Y., & Hu, A. (2014) · Journal of Materials Chemistry C · doi:10.1039/c4tc00988f · Cited by 2,597
Self-citationUpconversion Luminescent Materials: Advances and Applications
Zhou, J., Liu, Q., Feng, W., Sun, Y., & Li, F. (2015) · Chemical Reviews · doi:10.1021/cr400478f · Cited by 2,254
Zheng, W., Huang, P., Tu, D., Ma, E., Zhu, H., & Chen, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00178h · Cited by 894
Nanostructured Sensors for Detection of Heavy Metals: A Review
Li, M., Gou, H., Al-Ogaidi, I., & Wu, N. (2013) · ACS Sustainable Chemistry & Engineering · doi:10.1021/sc400019a · Cited by 606
Liu, Y., Duan, W., Song, W., Liu, J., Ren, C., Wu, J., Liu, D., & Chen, H. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b15746 · Cited by 521
Metadata
- Authors
- Wang, Y., Bao, L., Liu, Z., & Pang, D.-W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-09-30
- Volume
- 83
- Issue
- 21
- Pages
- 8130-8137
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2080624874
- Cited by
- 372
- References
- 31
- FWCI
- 13.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.