The DOI matches its Crossref record.
Amplified Surface Plasmon Resonance and Electrochemical Detection of Pb2+ Ions Using the Pb2+-Dependent DNAzyme and Hemin/G-Quadruplex as a Label
Abstract
The hemin/G-quadruplex nanostructure and the Pb(2+)-dependent DNAzyme are implemented to develop sensitive surface plasmon resonance (SPR) and electrochemical sensing platforms for Pb(2+) ions. A complex consisting of the Pb(2+)-dependent DNAzyme sequence and a ribonuclease-containing nucleic acid sequence (corresponding to the substrate of the DNAzyme) linked to a G-rich domain, which is "caged" in the complex structure, is assembled on Au-coated glass surfaces or Au electrodes. In the presence of Pb(2+) ions, the Pb(2+)-dependent DNAzyme cleaves the substrate, leading to the separation of the complex and to the self-assembly of the hemin/G-quadruplex on the Au support. In one sensing platform, the Pb(2+) ions are analyzed by following the dielectric changes at the surface as a result of the formation of the hemin/G-quadruplex label using SPR. This sensing platform is further amplified by the immobilization of the sensing complex on Au NPs (13 nm) and using the electronic coupling between the NPs and the surface plasmon wave as an amplification mechanism. This method enables the sensing of Pb(2+) ions with a detection limit that corresponds to 5 fM. The second sensing platform implements the resulting hemin/G-quadruplex as an electrocatalytic label that catalyzes the electrochemical reduction of H(2)O(2). This method enables the detection of Pb(2+) with a detection limit of 1 pM. Both sensing platforms reveal selectivity toward the detection of Pb(2+) ions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhou, W., Saran, R., & Liu, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00063 · Cited by 931
Wang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Self-citationTriplex DNA Nanostructures: From Basic Properties to Applications
Hu, Y., Cecconello, A., Idili, A., Ricci, F., & Willner, I. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201701868 · Cited by 336
Self-citationDNAzyme-based biosensors and nanodevices
Gong, L., Zhao, Z., Lv, Y.-F., Huan, S.-Y., Fu, T., Zhang, X.-B., Shen, G.-L., & Yu, R.-Q. (2015) · Chemical Communications · doi:10.1039/c4cc06855f · Cited by 321
Photonic Nanosensor for Colorimetric Detection of Metal Ions
Yetisen, A. K., Montelongo, Y., Qasim, M. M., Butt, H., Wilkinson, T. D., Monteiro, M. J., & Yun, S. H. (2015) · Analytical Chemistry · doi:10.1021/ac504274q · Cited by 94
Metadata
- Authors
- Pelossof, G., Tel-Vered, R., & Willner, I.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-04-04
- Volume
- 84
- Issue
- 8
- Pages
- 3703-3709
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1981283567
- Cited by
- 206
- References
- 0
- FWCI
- 9.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Amplified Surface Plasmon Resonance and Electrochemical Detection of Pb2+ Ions Using the Pb2+-Dependent DNAzyme and Hemin/G-Quadruplex as a Label. https://app.cochat.ai/papers/10.1021/ac3002269
- The paper
- Pelossof, G., Tel-Vered, R., & Willner, I. (2012). Amplified Surface Plasmon Resonance and Electrochemical Detection of Pb2+ Ions Using the Pb2+-Dependent DNAzyme and Hemin/G-Quadruplex as a Label. Analytical Chemistry. https://doi.org/10.1021/ac3002269
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.