The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Cancer Biomarker Detection in Serum Samples Using Surface Plasmon Resonance and Quartz Crystal Microbalance Sensors with Nanoparticle Signal Amplification
Abstract
Early detection of cancer is vital for the successful treatment of the disease. Hence, a rapid and sensitive diagnosis is essential before the cancer is spread out to the other body organs. Here we describe the development of a point-of-care immunosensor for the detection of the cancer biomarker (total prostate-specific antigen, tPSA) using surface plasmon resonance (SPR) and quartz crystal microbalance (QCM) sensor platforms in human serum samples. K(D) of the antibody used toward PSA was calculated as 9.46 × 10(-10) M, indicating high affinity of the antibody used in developing the assay. By performing a sandwich assay using antibody-modified nanoparticles concentrations of 2.3 ng mL(-1) (Au, 20 nm) and 0.29 ng mL(-1) (8.5 pM) (Au, 40 nm) tPSA in 75% human serum were detected using the developed assay on an SPR sensor chip. The SPR sensor results were found to be comparable to that achieved using a QCM sensor platform, indicating that both systems can be applied for disease biomarkers screening. The clinical applicability of the developed immunoassay can therefore be successfully applied to patient's serum samples. This demonstrates the high potential of the developed sensor devices as platforms for clinical prostate cancer diagnosis and prognosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
A Review on Functionalized Gold Nanoparticles for Biosensing Applications
Zeng, S., Yong, K.-T., Roy, I., Dinh, X.-Q., Yu, X., & Luan, F. (2011) · Plasmonics · doi:10.1007/s11468-011-9228-1 · Cited by 754
Höök, F., Vörös, J., Rodahl, M., Kurrat, R., Böni, P., Ramsden, J. J., Textor, M., Spencer, N. D., Tengvall, P., Gold, J., et al. (2002) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(01)00236-3 · Cited by 671
Advances in surface plasmon resonance biosensor analysis
Rich, R. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00054-3 · Cited by 665
Schweitzer, B., Wiltshire, S., Lambert, J., O'Malley, S., Kukanskis, K., Zhu, Z., Kingsmore, S. F., Lizardi, P. M., & Ward, D. C. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170237197 · Cited by 597
Fägerstam, L. G., Frostell-Karlsson, Å., Karlsson, R., Persson, B., & Rönnberg, I. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)80137-j · Cited by 437
Lilja, H., Oldbring, J., Rannevik, G., & Laurell, C. B. (1987) · Journal of Clinical Investigation · doi:10.1172/jci113070 · Cited by 395
Analyzing a kinetic titration series using affinity biosensors
Karlsson, R., Katsamba, P. S., Nordin, H., Pol, E., & Myszka, D. G. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2005.09.034 · Cited by 382
Cooper, M. A., & Singleton, V. T. (2007) · Journal of Molecular Recognition · doi:10.1002/jmr.826 · Cited by 370
Applications of nanotechnology to biotechnology
West, J. L., & Halas, N. J. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(00)00082-3 · Cited by 342
Surface Plasmon Resonance Biosensing
Piliarik, M., Vaisocherová, H., & Homola, J. (2009) · Methods in Molecular Biology · doi:10.1007/978-1-60327-567-5_5 · Cited by 238
Huang, L., Reekmans, G., Saerens, D., Friedt, J.-M., Frederix, F., Francis, L., Muyldermans, S., Campitelli, A., & Hoof, C. V. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.016 · Cited by 215
Kinetic analysis of a high-affinity antibody/antigen interaction performed by multiple Biacore users
Katsamba, P. S., Navratilova, I., Calderon-Cacia, M., Fan, L., Thornton, K., Zhu, M., Bos, T. V., Forte, C., Friend, D., Laird-Offringa, I., et al. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.01.034 · Cited by 185
Prostate-specific Antigen: Its Usefulness in Clinical Medicine
Diamandis, E. P. (1998) · Trends in Endocrinology & Metabolism · doi:10.1016/s1043-2760(98)00082-4 · Cited by 166
Mustafa, D. E., Yang, T., Xuan, Z., et al. (2010) · Plasmonics · doi:10.1007/s11468-010-9141-z · Cited by 128
Label-Free Biosensors: Techniques and Applications
Cooper, M. A. (2009) · Cited by 93
Choi, J., Kang, D.-Y., Jang, Y.-H., Kim, H.-H., Min, J., & Oh, B. (2007) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2007.05.057 · Cited by 78
Nash, A., & Melezínek, I. (2000) · Endocrine Related Cancer · doi:10.1677/erc.0.0070037 · Cited by 67
Situ, C., Wylie, A. R. G., DOUGLAS, A., & Elliott, C. T. (2008) · Talanta · doi:10.1016/j.talanta.2008.04.053 · Cited by 41
Cited by
Plasmon-enhanced optical sensors: a review
Li, M., Cushing, S. K., & Wu, N. (2015) · The Analyst · doi:10.1039/c4an01079e · Cited by 1,011
Sandwich-type immunosensors and immunoassays exploiting nanostructure labels: A review
Pei, X., Zhang, B., Tang, J., Liu, B., Lai, W., & Tang, D. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.10.060 · Cited by 454
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Zhang, L., Mazouzi, Y., Salmain, M., Liedberg, B., & Boujday, S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112370 · Cited by 258
Metadata
- Authors
- Uludag, Y., & Tothill, I. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-06-25
- Volume
- 84
- Issue
- 14
- Pages
- 5898-5904
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1998230670
- Cited by
- 290
- References
- 19
- FWCI
- 9.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.