The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Cancer Biomarker Detection in Serum Samples Using Surface Plasmon Resonance and Quartz Crystal Microbalance Sensors with Nanoparticle Signal Amplification
Abstract
Early detection of cancer is vital for the successful treatment of the disease. Hence, a rapid and sensitive diagnosis is essential before the cancer is spread out to the other body organs. Here we describe the development of a point-of-care immunosensor for the detection of the cancer biomarker (total prostate-specific antigen, tPSA) using surface plasmon resonance (SPR) and quartz crystal microbalance (QCM) sensor platforms in human serum samples. K(D) of the antibody used toward PSA was calculated as 9.46 × 10(-10) M, indicating high affinity of the antibody used in developing the assay. By performing a sandwich assay using antibody-modified nanoparticles concentrations of 2.3 ng mL(-1) (Au, 20 nm) and 0.29 ng mL(-1) (8.5 pM) (Au, 40 nm) tPSA in 75% human serum were detected using the developed assay on an SPR sensor chip. The SPR sensor results were found to be comparable to that achieved using a QCM sensor platform, indicating that both systems can be applied for disease biomarkers screening. The clinical applicability of the developed immunoassay can therefore be successfully applied to patient's serum samples. This demonstrates the high potential of the developed sensor devices as platforms for clinical prostate cancer diagnosis and prognosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
A Review on Functionalized Gold Nanoparticles for Biosensing Applications
Zeng, S., Yong, K.-T., Roy, I., Dinh, X.-Q., Yu, X., & Luan, F. (2011) · Plasmonics · doi:10.1007/s11468-011-9228-1 · Cited by 754
Höök, F., Vörös, J., Rodahl, M., Kurrat, R., Böni, P., Ramsden, J. J., Textor, M., Spencer, N. D., Tengvall, P., Gold, J., et al. (2002) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(01)00236-3 · Cited by 671
Advances in surface plasmon resonance biosensor analysis
Rich, R. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00054-3 · Cited by 665
Schweitzer, B., Wiltshire, S., Lambert, J., O'Malley, S., Kukanskis, K., Zhu, Z., Kingsmore, S. F., Lizardi, P. M., & Ward, D. C. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170237197 · Cited by 597
Fägerstam, L. G., Frostell-Karlsson, Å., Karlsson, R., Persson, B., & Rönnberg, I. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)80137-j · Cited by 437
Lilja, H., Oldbring, J., Rannevik, G., & Laurell, C. B. (1987) · Journal of Clinical Investigation · doi:10.1172/jci113070 · Cited by 395
Analyzing a kinetic titration series using affinity biosensors
Karlsson, R., Katsamba, P. S., Nordin, H., Pol, E., & Myszka, D. G. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2005.09.034 · Cited by 382
Cooper, M. A., & Singleton, V. T. (2007) · Journal of Molecular Recognition · doi:10.1002/jmr.826 · Cited by 370
Applications of nanotechnology to biotechnology
West, J. L., & Halas, N. J. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(00)00082-3 · Cited by 342
Cited by
Surface Plasmon Resonance: A Versatile Technique for Biosensor Applications
Nguyen, H., Park, J., Kang, S., & Kim, M. (2015) · Sensors · doi:10.3390/s150510481 · Cited by 1,357
Plasmon-enhanced optical sensors: a review
Li, M., Cushing, S. K., & Wu, N. (2015) · The Analyst · doi:10.1039/c4an01079e · Cited by 1,011
Nanoparticle-Based Immunochemical Biosensors and Assays: Recent Advances and Challenges
Farka, Z., Juřík, T., Kovář, D., Trnková, L., & Skládal, P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00037 · Cited by 694
Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics
Masson, J.-F. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00763 · Cited by 663
Xu, Y., Bai, P., Zhou, X., Akimov, Y., Png, C. E., Ang, L., Knoll, W., & Wu, L. (2019) · Advanced Optical Materials · doi:10.1002/adom.201801433 · Cited by 519
Sandwich-type immunosensors and immunoassays exploiting nanostructure labels: A review
Pei, X., Zhang, B., Tang, J., Liu, B., Lai, W., & Tang, D. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.10.060 · Cited by 454
Advances in Plasmonic Technologies for Point of Care Applications
Tokel, O., Inci, F., & Demirci, U. (2014) · Chemical Reviews · doi:10.1021/cr4000623 · Cited by 407
Surface Plasmon Resonance (SPR) Biosensors in Pharmaceutical Analysis
Olaru, A., Bala, C., Jaffrezic-Renault, N., & Aboul-Enein, H. Y. (2015) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2014.881250 · Cited by 400
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Pires, N., Dong, T., Hanke, U., & Hoivik, N. (2014) · Sensors · doi:10.3390/s140815458 · Cited by 307
Trends and challenges of refractometric nanoplasmonic biosensors: A review
Estevez, M.-C., Otte, M. A., Sepulveda, B., & Lechuga, L. M. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.10.048 · Cited by 301
Mittal, S., Kaur, H., Gautam, N., & Mantha, A. K. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.028 · Cited by 295
Highly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
Point of care testing for infectious diseases
Chen, H., Liu, K., Li, Z., & Wang, P. (2019) · Clinica Chimica Acta · doi:10.1016/j.cca.2019.03.008 · Cited by 270
Zhang, L., Mazouzi, Y., Salmain, M., Liedberg, B., & Boujday, S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112370 · Cited by 258
Metadata
- Authors
- Uludag, Y., & Tothill, I. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-06-25
- Volume
- 84
- Issue
- 14
- Pages
- 5898-5904
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1998230670
- Cited by
- 290
- References
- 19
- FWCI
- 9.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.