Electrothermal Supercharging of Proteins in Native Electrospray Ionization
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The formation of high charge-state protein ions with nanoelectrospray ionization (nESI) from purely aqueous ammonium bicarbonate solutions at neutral pH, where the proteins have native or native-like conformations prior to ESI droplet formation, is demonstrated. This "electrothermal" supercharging method depends on the temperature of the instrument entrance capillary, the nESI spray potential, and the solution ionic strength and buffer, although other factors almost certainly contribute. Mass spectra obtained with electrothermal supercharging appear similar to those obtained from denaturing solutions where charging beyond the total number of basic sites can be achieved. For example, a 17+ ion of bovine ubiquitin was formed by nESI of a 100 mM ammonium bicarbonate, pH 7.0, solution, which is three more charges than the total number of basic amino acids plus the N-terminus. Heating of the ESI droplets in the vacuum/atmosphere interface and the concomitant denaturation of the protein in the ESI droplets prior to ion formation appears to be the primary origin of the very high charge-state ions formed from these purely aqueous, buffered solutions. nESI mass spectra resembling those obtained under traditional native or denaturing conditions can be reversibly obtained simply by toggling the spray voltage between low and high values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Native mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766
On the Scalability and Requirements of Whole Protein Mass Spectrometry
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac2010795 · Cited by 243
Valeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Cited by
Hedges, J. B., Vahidi, S., Yue, X., & Konermann, L. (2013) · Analytical Chemistry · doi:10.1021/ac401020s · Cited by 109
Zhou, M., Dagan, S., & Wysocki, V. H. (2013) · The Analyst · doi:10.1039/c2an36525a · Cited by 92
Gavriilidou, A. F. M., Gülbakan, B., & Zenobi, R. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02478 · Cited by 53
Metadata
- Authors
- Sterling, H. J., Cassou, C. A., Susa, A. C., & Williams, E. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-03-19
- Volume
- 84
- Issue
- 8
- Pages
- 3795-3801
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1973333093
- Cited by
- 85
- References
- 5
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.