CoChat

Long-Gradient Separations Coupled with Selected Reaction Monitoring for Highly Sensitive, Large Scale Targeted Protein Quantification in a Single Analysis

Open access
Shi, Tujin, Fillmore, Thomas L., Gao, Yuqian, Zhao, Rui, He, Jintang, Schepmoes, Athena A., Nicora, Carrie D., Wu, Chaochao, Chambers, Justin L., Moore, Ronald J., Kagan, Jacob, Srivastava, Sudhir, Liu, Alvin Y., Rodland, Karin D., Liu, Tao, Camp, David G., Smith, Richard D., Qian, Wei-Jun · 2013 · Analytical Chemistry
Cited by 43

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Long-gradient separations coupled to tandem mass spectrometry (MS) were recently demonstrated to provide a deep proteome coverage for global proteomics; however, such long-gradient separations have not been explored for targeted proteomics. Herein, we investigate the potential performance of the long-gradient separations coupled with selected reaction monitoring (LG-SRM) for targeted protein quantification. Direct comparison of LG-SRM (5 h gradient) and conventional liquid chromatography (LC)-SRM (45 min gradient) showed that the long-gradient separations significantly reduced background interference levels and provided an 8- to 100-fold improvement in limit of quantification (LOQ) for target proteins in human female serum. On the basis of at least one surrogate peptide per protein, an LOQ of 10 ng/mL was achieved for the two spiked proteins in nondepleted human serum. The LG-SRM detection of seven out of eight endogenous plasma proteins expressed at ng/mL or subng/mL levels in clinical patient sera was also demonstrated. A correlation coefficient of >0.99 was observed for the results of LG-SRM and enzyme-linked immunosorbent assay (ELISA) measurements for prostate-specific antigen (PSA) in selected patient sera. Further enhancement of LG-SRM sensitivity was achieved by applying front-end IgY14 immunoaffinity depletion. Besides improved sensitivity, LG-SRM potentially offers much higher multiplexing capacity than conventional LC-SRM due to an increase in average peak widths (~3-fold) for a 300 min gradient compared to a 45 min gradient. Therefore, LG-SRM holds great potential for bridging the gap between global and targeted proteomics due to its advantages in both sensitivity and multiplexing capacity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac402105s

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 43

Metadata

Authors
Shi, T., Fillmore, T. L., Gao, Y., Zhao, R., He, J., Schepmoes, A. A., Nicora, C. D., Wu, C., Chambers, J. L., Moore, R. J., Kagan, J., Srivastava, S., Liu, A. Y., Rodland, K. D., Liu, T., Camp, D. G., Smith, R. D., & Qian, W.-J.
Venue
Analytical Chemistry
Published
2013-09-19
Volume
85
Issue
19
Pages
9196-9203
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2072753883
Cited by
43
References
9
FWCI
3.43
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-Gradient Separations Coupled with Selected Reaction Monitoring for Highly Sensitive, Large Scale Targeted Protein Quantification in a Single Analysis. https://app.cochat.ai/papers/10.1021/ac402105s
The paper
Shi, T., Fillmore, T. L., Gao, Y., Zhao, R., He, J., Schepmoes, A. A., Nicora, C. D., Wu, C., Chambers, J. L., Moore, R. J., Kagan, J., Srivastava, S., Liu, A. Y., Rodland, K. D., Liu, T., Camp, D. G., Smith, R. D., & Qian, W.-J. (2013). Long-Gradient Separations Coupled with Selected Reaction Monitoring for Highly Sensitive, Large Scale Targeted Protein Quantification in a Single Analysis. Analytical Chemistry. https://doi.org/10.1021/ac402105s

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.