The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Cost-Effective Three-Dimensional Printing of Visibly Transparent Microchips within Minutes
Open accessAbstract
One-step fabrication of transparent three-dimensional (3D) microfluidic to millifluidic devices was demonstrated using a commercial 3D printer costing $2300 with 500 mL of clear resin for $138. It employs dynamic mask projection stereolithography, allowing fast concept-to-chip time. The fully automated system allows fabrication of models of up to 43 mm × 27 mm × 180 mm (x × y × z) at printing speeds of 20 mm/h in height regardless of the design complexity. The minimal cross sectional area of 250 μm was achieved for monolithic microchannels and 200 μm for positive structures (templates for soft lithography). The colorless resin's good light transmittance (>60% transmission at wavelengths of >430 nm) allows for on-chip optical detection, while the electrically insulating material allows electrophoretic separations. To demonstrate its applicability in microfluidics, the printer was used for the fabrication of a micromixer, a gradient generator, a droplet extractor, and a device for isotachophoresis. The mixing and gradient formation units were incorporated into a device for analysis of nitrate in tap water with standard addition as a single run and multiple depth detection cells to provide an extended linear range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
A review on 3D micro-additive manufacturing technologies
Vaezi, M., Seitz, H., & Yang, S. (2013) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-012-4605-2 · Cited by 1,293
Levy, G. N., Schindel, R., & Kruth, J. P. (2003) · CIRP Annals · doi:10.1016/s0007-8506(07)60206-6 · Cited by 1,121
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Projection micro-stereolithography using digital micro-mirror dynamic mask
Sun, C., Fang, N., Wu, D. M., & Zhang, X. (2005) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2004.12.011 · Cited by 880
Maskless fabrication of light-directed oligonucleotide microarrays using a digital micromirror array
Singh-Gasson, S., Green, R. D., Yue, Y., Nelson, C., Blattner, F., Sussman, M. R., & Cerrina, F. (1999) · Nature Biotechnology · doi:10.1038/13664 · Cited by 733
Chaotic mixing in three-dimensional microvascular networks fabricated by direct-write assembly
Therriault, D., White, S. R., & Lewis, J. A. (2003) · Nature Materials · doi:10.1038/nmat863 · Cited by 707
Integrated 3D-printed reactionware for chemical synthesis and analysis
Symes, M. D., Kitson, P. J., Yan, J., Richmond, C. J., Cooper, G. J. T., Bowman, R. W., Vilbrandt, T., & Cronin, L. (2012) · Nature Chemistry · doi:10.1038/nchem.1313 · Cited by 617
Configurable 3D-Printed millifluidic and microfluidic ‘lab on a chip’ reactionware devices
Kitson, P. J., Rosnes, M. H., Sans, V., Dragone, V., & Cronin, L. (2012) · Lab on a Chip · doi:10.1039/c2lc40761b · Cited by 484
Waldbaur, A., Rapp, H., Länge, K., & Rapp, B. E. (2011) · Analytical Methods · doi:10.1039/c1ay05253e · Cited by 381
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
The upcoming 3D-printing revolution in microfluidics
Bhattacharjee, N., Urrios, A., Kang, S., & Folch, A. (2016) · Lab on a Chip · doi:10.1039/c6lc00163g · Cited by 1,123
3D printed microfluidic devices: enablers and barriers
Waheed, S., Cabot, J. M., Macdonald, N. P., Lewis, T., Guijt, R. M., Paull, B., & Breadmore, M. C. (2016) · Lab on a Chip · doi:10.1039/c6lc00284f · Cited by 1,039
Self-citationAu, A. K., Huynh, W., Horowitz, L. F., & Folch, A. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201504382 · Cited by 788
Projection micro stereolithography based 3D printing and its applications
Ge, Q., Li, Z., Wang, Z., Kowsari, K., Zhang, W., He, X., Zhou, J., & Fang, N. X. (2020) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ab8d9a · Cited by 444
Comparing Microfluidic Performance of Three-Dimensional (3D) Printing Platforms
Macdonald, N. P., Cabot, J. M., Smejkal, P., Guijt, R. M., Paull, B., & Breadmore, M. C. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00136 · Cited by 425
Self-citationLee, H., & Cho, D.-W. (2016) · Lab on a Chip · doi:10.1039/c6lc00450d · Cited by 363
Recent Advances in Analytical Chemistry by 3D Printing
Gross, B., Lockwood, S. Y., & Spence, D. M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04344 · Cited by 359
Nielsen, A. V., Beauchamp, M. J., Nordin, G. P., & Woolley, A. T. (2020) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-091619-102649 · Cited by 339
Developments of 3D Printing Microfluidics and Applications in Chemistry and Biology: a Review
He, Y., Wu, Y., Fu, J., Gao, Q., & Qiu, J. (2016) · Electroanalysis · doi:10.1002/elan.201600043 · Cited by 313
3D printing for chemical, pharmaceutical and biological applications
Capel, A. J., Rimington, R. P., Lewis, M. P., & Christie, S. D. R. (2018) · Nature Reviews Chemistry · doi:10.1038/s41570-018-0058-y · Cited by 312
Simple 3D Printed Scaffold‐Removal Method for the Fabrication of Intricate Microfluidic Devices
Saggiomo, V., & Velders, A. H. (2015) · Advanced Science · doi:10.1002/advs.201500125 · Cited by 266
High density 3D printed microfluidic valves, pumps, and multiplexers
Gong, H., Woolley, A. T., & Nordin, G. P. (2016) · Lab on a Chip · doi:10.1039/c6lc00565a · Cited by 263
Fully 3D-Printed Preconcentrator for Selective Extraction of Trace Elements in Seawater
Su, C.-K., Peng, P.-J., & Sun, Y.-C. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01599 · Cited by 111
Li, F., Macdonald, N. P., Guijt, R. M., & Breadmore, M. C. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03228 · Cited by 74
Self-citation3D printed device for the automated preconcentration and determination of chromium (VI)
Calderilla, C., Maya, F., Cerdà, V., & Leal, L. O. (2018) · Talanta · doi:10.1016/j.talanta.2018.02.065 · Cited by 68
Calderilla, C., Maya, F., Cerdà, V., & Leal, L. O. (2017) · Talanta · doi:10.1016/j.talanta.2017.07.028 · Cited by 54
Metadata
- Authors
- Shallan, A. I., Smejkal, P., Corban, M., Guijt, R. M., & Breadmore, M. C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-02-24
- Volume
- 86
- Issue
- 6
- Pages
- 3124-3130
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1981080311
- Cited by
- 501
- References
- 29
- FWCI
- 26.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.