CoChat

pQuant Improves Quantitation by Keeping out Interfering Signals and Evaluating the Accuracy of Calculated Ratios

Liu, Chao, Song, Chun-Qing, Yuan, Zuo-Fei, Fu, Yan, Chi, Hao, Wang, Le-Heng, Fan, Sheng-Bo, Zhang, Kun, Zeng, Wen-Feng, He, Si-Min, Dong, Meng-Qiu, Sun, Rui-Xiang · 2014 · Analytical Chemistry
Cited by 84

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

In relative protein abundance determination from peptide intensities recorded in full mass scans, a major complication that affects quantitation accuracy is signal interference from coeluting ions of similar m/z values. Here, we present pQuant, a quantitation software tool that solves this problem. pQuant detects interference signals, identifies for each peptide a pair of least interfered isotopic chromatograms: one for the light and one for the heavy isotope-labeled peptide. On the basis of these isotopic pairs, pQuant calculates the relative heavy/light peptide ratios along with their 99.75% confidence intervals (CIs). From the peptides ratios and their CIs, pQuant estimates the protein ratios and associated CIs by kernel density estimation. We tested pQuant, Census and MaxQuant on data sets obtained from mixtures (at varying mixing ratios from 10:1 to 1:10) of light- and heavy-SILAC labeled HeLa cells or (14)N- and (15)N-labeled Escherichia coli cells. pQuant quantitated more peptides with better accuracy than Census and MaxQuant in all 14 data sets. On the SILAC data sets, the nonquantified "NaN" (not a number) ratios generated by Census, MaxQuant, and pQuant accounted for 2.5-10.7%, 1.8-2.7%, and 0.01-0.5% of all ratios, respectively. On the (14)N/(15)N data sets, which cannot be quantified by MaxQuant, Census and pQuant produced 0.9-10.0% and 0.3-2.9% NaN ratios, respectively. Excluding these NaN results, the standard deviations of the numerical ratios calculated by Census or MaxQuant are 30-100% larger than those by pQuant. These results show that pQuant outperforms Census and MaxQuant in SILAC and (15)N-based quantitation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac404246w

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Liu, C., Song, C.-Q., Yuan, Z.-F., Fu, Y., Chi, H., Wang, L.-H., Fan, S.-B., Zhang, K., Zeng, W.-F., He, S.-M., Dong, M.-Q., & Sun, R.-X.
Venue
Analytical Chemistry
Published
2014-05-13
Volume
86
Issue
11
Pages
5286-5294
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2171065132
Cited by
84
References
7
FWCI
2.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.