The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Carbon-Dot-Based Ratiometric Fluorescent Probe for Imaging and Biosensing of Superoxide Anion in Live Cells
Abstract
In this article, a ratiometric fluorescent biosensor for O2(•-) was developed, by employing carbon dots (C-Dots) as the reference fluorophore and hydroethidine (HE), a specific organic molecule toward O2(•-), playing the role as both specific recognition element and response signal. The hybrid fluorescent probe CD-HE only emitted at 525 nm is ascribed to C-Dots, while HE was almost nonfluorescent, upon excitation at 488 nm. However, after reaction with O2(•-), a new emission peak ascribed to the reaction products of HE and O2(•-) was clearly observed at 610 nm. Meanwhile, this peak gradually increased with the increasing concentration of O2(•-) but the emission peak at 525 nm stayed constant, leading to a ratiometric detection of O2(•-). The inorganic-organic fluorescent sensor exhibited high sensitivity, a broad dynamic linear range of ~5 × 10(-7)-1.4 × 10(-4) M, and low detection limit down to 100 nM. The present probe also showed high accuracy and excellent selectivity for O2(•-) over other reactive oxygen species (ROS), metal ions, and so on. Moreover, the C-Dot-based inorganic-organic probe demonstrated long-term stability against pH changes and continuous light illumination, good cell-permeability, and low cytotoxicity. Accordingly, the developed fluorescent biosensor was eventually applied for intracellular bioimaging and biosensing of O2(•-) changes upon oxidative stress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Superoxide dismutases and superoxide reductases
Sheng, Y., Abreu, I. A., Cabelli, D. E., Maroney, M. J., Miller, A.-F., Teixeira, M., & Valentine, J. S. (2014) · Chemical Reviews · doi:10.1021/cr4005296 · Cited by 1,081
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Selective fluorescent imaging of superoxide in vivo using ethidium-based probes
Robinson, K. M., Janes, M. S., Pehar, M., Monette, J. S., Ross, M. F., Hagen, T. M., Murphy, M. P., & Beckman, J. S. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0601945103 · Cited by 777
Gao, J. J., Xu, K. H., Tang, B., Yin, L. L., Yang, G. W., & An, L. G. (2007) · The FEBS Journal · doi:10.1111/j.1742-4658.2007.05720.x · Cited by 76
Cited by
Fluorescent carbon dots and their sensing applications
Sun, X., & Lei, Y. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.02.001 · Cited by 839
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Tao, Y., Ju, E., Ren, J., & Qu, X. (2015) · Advanced Materials · doi:10.1002/adma.201405105 · Cited by 620
Nanocarbons for Biology and Medicine: Sensing, Imaging, and Drug Delivery
Panwar, N., Soehartono, A. M., Chan, K. K., Zeng, S., Xu, G., Qu, J., Coquet, P., Yong, K.-T., & Chen, X. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00099 · Cited by 555
Recent developments in carbon nanomaterial sensors
Baptista, F. R., Belhout, S. A., Giordani, S., & Quinn, S. J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00379a · Cited by 541
Metadata
- Authors
- Gao, X., Ding, C., Zhu, A., & Tian, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-06-27
- Volume
- 86
- Issue
- 14
- Pages
- 7071-7078
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2316102145
- Cited by
- 227
- References
- 4
- FWCI
- 11.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon-Dot-Based Ratiometric Fluorescent Probe for Imaging and Biosensing of Superoxide Anion in Live Cells. https://app.cochat.ai/papers/10.1021/ac501499y
- The paper
- Gao, X., Ding, C., Zhu, A., & Tian, Y. (2014). Carbon-Dot-Based Ratiometric Fluorescent Probe for Imaging and Biosensing of Superoxide Anion in Live Cells. Analytical Chemistry. https://doi.org/10.1021/ac501499y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.