The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In Situ Growth of Surfactant-Free Gold Nanoparticles on Nitrogen-Doped Graphene Quantum Dots for Electrochemical Detection of Hydrogen Peroxide in Biological Environments
Abstract
In this work, we report a green and simple strategy for the in situ growth of surfactant-free Au nanoparticles (Au NPs) on nitrogen-doped graphene quantum dots (Au NPs-N-GQDs). The formation of hybrid was achieved by just mixing the N-GQDs and HAuCl4·4H2O without addition of any other reductant and surfactant. High-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS) characterizations clearly showed the formation of Au nanoparticles with predominantly exposed (111) facets which can provide more adsorption sites. Such nonsurfactant-capped Au NPs can provide naked catalytic surface with highly electrocatalytic activity. The Au NPs-N-GQDs exhibit high sensitivity and selectivity for electrochemical detection of hydrogen peroxide (H2O2) with a low detection limit of 0.12 μM and sensitivity of 186.22 μA/mM cm(2). Importantly, the Au NPs-N-GQDs-based electrochemical biosensor has shown great potential applications for detection of H2O2 levels in human serum samples and that released from human cervical cancer cells with satisfactory results. The present study demonstrates that such novel Au NPs-N-GQDs nanocomposite is promising for fabrication of nonenzymatic H2O2 biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructured Pt-alloy electrocatalysts for PEM fuel cell oxygen reduction reaction
Bing, Y., Liu, H., Zhang, L., Ghosh, D., & Zhang, J. (2010) · Chemical Society Reviews · doi:10.1039/b912552c · Cited by 1,154
Cited by
New Generation Cadmium-Free Quantum Dots for Biophotonics and Nanomedicine
Xu, G., Zeng, S., Zhang, B., Swihart, M. T., Yong, K.-T., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00290 · Cited by 587
Atchudan, R., Edison, T. N. J. I., Chakradhar, D., Perumal, S., Shim, J.-J., & Lee, Y. R. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.02.119 · Cited by 426
Synthesis and applications of graphene quantum dots: a review
Chen, W., Lv, G., Hu, W., Li, D., Chen, S., & Dai, Z. (2018) · Nanotechnology Reviews · doi:10.1515/ntrev-2017-0199 · Cited by 394
Self-citationOrgans-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
Theerthagiri, J., Lee, S. J., Karuppasamy, K., Park, J., Yu, Y., Kumari, M. L. A., Chandrasekaran, S., Kim, H.-S., & Choi, M. Y. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.126648 · Cited by 85
Metadata
- Authors
- Ju, J., & Chen, W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-01-09
- Volume
- 87
- Issue
- 3
- Pages
- 1903-1910
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2323748430
- Cited by
- 567
- References
- 1
- FWCI
- 32.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.