Real-Time Microfluidic System for Studying Mammalian Cells in 3D Microenvironments
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We describe a microfluidic system that can control, in real time, the microenvironments of mammalian cells in naturally derived 3D extracellular matrix (ECM). This chip combines pneumatically actuated valves with an individually addressable array of 3D cell-laden ECM; actuation of valves determines the pathways for delivering reagents through the chip and for exchanging diffusible factors between cell chambers. To promote rapid perfusion of reagents through 3D gels (with complete exchange of reagents within the gel in seconds), we created conduits above the gels for fluid flow, and microposts to stabilize the gels under high perfusion rates. As a biological demonstration, we studied spatially segregated mouse embryonic stem cells and mouse embryonic fibroblasts embedded in 3D Matrigel over days of culture. Overall, this system may be useful for high-throughput screening, single-cell analysis and studies of cell-cell communication, where rapid control of 3D cellular microenvironments is desired.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Taking Cell-Matrix Adhesions to the Third Dimension
Cukierman, E., Pankov, R., Stevens, D. R., & Yamada, K. M. (2001) · Science · doi:10.1126/science.1064829 · Cited by 3,027
A novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414
Cited by
Designing materials to direct stem-cell fate
Lutolf, M. P., Gilbert, P. M., & Blau, H. M. (2009) · Nature · doi:10.1038/nature08602 · Cited by 1,393
Revisiting lab-on-a-chip technology for drug discovery
Neužil, P., Giselbrecht, S., Länge, K., Huang, T. J., & Manz, A. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3799 · Cited by 487
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Oriented collagen fibers direct tumor cell intravasation
Han, W., Chen, S., Yuan, W., Fan, Q., Tian, J., Wang, X., Chen, L., Zhang, X., Wei, W., Liu, R., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1610347113 · Cited by 376
Laser-based direct-write techniques for cell printing
Schiele, N. R., Corr, D. T., Huang, Y., Raof, N. A., Xie, Y., & Chrisey, D. B. (2010) · Biofabrication · doi:10.1088/1758-5082/2/3/032001 · Cited by 334
Metadata
- Authors
- Lii, J., Hsu, W.-J., Parsa, H., Das, A., Rouse, R., & Sia, S. K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-04-08
- Volume
- 80
- Issue
- 10
- Pages
- 3640-3647
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1991396730
- Cited by
- 91
- References
- 2
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.