The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Matrix-Assisted Laser Desorption/Ionization-Ion Mobility Separation-Mass Spectrometry Imaging of Vinblastine in Whole Body Tissue Sections
Abstract
During early-stage drug development, drug and metabolite distribution studies are carried out in animal tissues using a range of techniques, particularly whole body autoradiography (WBA). While widely employed, WBA has a number of limitations, including the following: expensive synthesis of radiolabeled drugs and analyte specificity and identification. WBA only images the radiolabel. MALDI MSI has been shown previously to be advantageous for imaging the distribution of a range of drugs and metabolites in whole body sections. Ion mobility separation (IMS) adds a further separation step to imaging experiments; demonstrated here is MALDI-IMS-MS whole body imaging of rats dosed at 6 mg/kg i.v. with an anticancer drug, vinblastine and shown is the distribution of the precursor ion m/z 811.4 and several product ions including m/z 793, 751, 733, 719, 691, 649, 524, and 355. The distribution of vinblastine within the ventricles of the brain is also depicted. Clearly demonstrated in these data are the removal of interfering isobaric ions within the images of m/z 811.4 and also of the transition m/z 811-751, resulting in a higher confidence in the imaging data. Within this work, IMS has shown to be advantageous in both MS and MS/MS imaging experiments by separating vinblastine from an endogenous isobaric lipid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234
Cited by
Lanucara, F., Holman, S. W., Gray, C. J., & Eyers, C. E. (2014) · Nature Chemistry · doi:10.1038/nchem.1889 · Cited by 901
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
Review on ion mobility spectrometry. Part 1: current instrumentation
Cumeras, R., Figueras, E., Davis, C. E., Baumbach, J. I., & Gràcia, I. (2015) · The Analyst · doi:10.1039/c4an01100g · Cited by 459
A concise review of mass spectrometry imaging
Amstalden van Hove, E. R., Smith, D. F., & Heeren, R. M. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.033 · Cited by 416
Molecular imaging by mass spectrometry — looking beyond classical histology
Schwamborn, K., & Caprioli, R. M. (2010) · Nature Reviews Cancer · doi:10.1038/nrc2917 · Cited by 354
Mass spectrometry imaging for drug distribution studies
Prideaux, B., & Stoeckli, M. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.07.028 · Cited by 279
MALDI imaging mass spectrometry: Spatial molecular analysis to enable a new age of discovery
Gessel, M. M., Norris, J. L., & Caprioli, R. M. (2014) · Journal of Proteomics · doi:10.1016/j.jprot.2014.03.021 · Cited by 276
Prideaux, B., Dartois, V., Staab, D., Weiner, D. M., Goh, A., Via, L. E., Barry, C. E., & Stoeckli, M. (2011) · Analytical Chemistry · doi:10.1021/ac1029049 · Cited by 260
Metadata
- Authors
- Trim, P. J., Henson, C. M., Avery, J. L., McEwen, A., Snel, M. F., Claude, E., Marshall, P. S., West, A., Princivalle, A. P., & Clench, M. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-10-11
- Volume
- 80
- Issue
- 22
- Pages
- 8628-8634
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1995342785
- Cited by
- 197
- References
- 1
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.