Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 409

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Ultralow Fouling and Functionalizable Surface Chemistry Based on a Zwitterionic Polymer Enabling Sensitive and Specific Protein Detection in Undiluted Blood Plasma

Vaisocherová, Hana, Yang, Wei, Zhang, Zheng, Cao, Zhiqiang, Cheng, Gang, Piliarik, Marek, Homola, Jiří, Jiang, Shaoyi·2008·Analytical Chemistry

Abstract

A crucial step in the development of implanted medical devices, in vivo diagnostics, and microarrays is the effective prevention of nonspecific protein adsorption from real-world complex media such as blood plasma or serum. In this work, a zwitterionic poly(carboxybetaine acrylamide) (polyCBAA) biomimetic material was employed to create a unique biorecognition coating with an ultralow fouling background, enabling the sensitive and specific detection of proteins in blood plasma. Conditions for surface activation, protein immobilization, and surface deactivation of the carboxylate groups in the polyCBAA coating were determined. An antibody-functionalized polyCBAA surface platform was used to detect a target protein in blood plasma using a sensitive surface plasmon resonance (SPR) sensor. A selective protein was directly detected from 100% human blood plasma with extraordinary specificity and sensitivity. The total nonspecific protein adsorption on the functionalized polyCBAA surface was very low (<3 ng/cm (2) for undiluted blood plasma). Because of the significant reduction of nonspecific protein adsorption, it was possible to monitor the kinetics of antigen-antibody interactions in undiluted blood plasma. The functionalization effectiveness and detection characteristics using a cancer protein marker candidate of polyCBAA were compared with those of the conventional nonfouling oligo(ethylene glycol)-based surface chemistry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac8015888

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 409

Metadata

Authors
Vaisocherová, H., Yang, W., Zhang, Z., Cao, Z., Cheng, G., Piliarik, M., Homola, J., & Jiang, S.
Venue
Analytical Chemistry
Published
2008-09-23
Volume
80
Issue
20
Pages
7894-7901
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2078739630
Cited by
409
References
1
FWCI
11.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultralow Fouling and Functionalizable Surface Chemistry Based on a Zwitterionic Polymer Enabling Sensitive and Specific Protein Detection in Undiluted Blood Plasma. https://app.cochat.ai/papers/10.1021/ac8015888
The paper
Vaisocherová, H., Yang, W., Zhang, Z., Cao, Z., Cheng, G., Piliarik, M., Homola, J., & Jiang, S. (2008). Ultralow Fouling and Functionalizable Surface Chemistry Based on a Zwitterionic Polymer Enabling Sensitive and Specific Protein Detection in Undiluted Blood Plasma. Analytical Chemistry. https://doi.org/10.1021/ac8015888

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.