The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Ultralow Fouling and Functionalizable Surface Chemistry Based on a Zwitterionic Polymer Enabling Sensitive and Specific Protein Detection in Undiluted Blood Plasma
Abstract
A crucial step in the development of implanted medical devices, in vivo diagnostics, and microarrays is the effective prevention of nonspecific protein adsorption from real-world complex media such as blood plasma or serum. In this work, a zwitterionic poly(carboxybetaine acrylamide) (polyCBAA) biomimetic material was employed to create a unique biorecognition coating with an ultralow fouling background, enabling the sensitive and specific detection of proteins in blood plasma. Conditions for surface activation, protein immobilization, and surface deactivation of the carboxylate groups in the polyCBAA coating were determined. An antibody-functionalized polyCBAA surface platform was used to detect a target protein in blood plasma using a sensitive surface plasmon resonance (SPR) sensor. A selective protein was directly detected from 100% human blood plasma with extraordinary specificity and sensitivity. The total nonspecific protein adsorption on the functionalized polyCBAA surface was very low (<3 ng/cm (2) for undiluted blood plasma). Because of the significant reduction of nonspecific protein adsorption, it was possible to monitor the kinetics of antigen-antibody interactions in undiluted blood plasma. The functionalization effectiveness and detection characteristics using a cancer protein marker candidate of polyCBAA were compared with those of the conventional nonfouling oligo(ethylene glycol)-based surface chemistry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Self-citationA Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Surface Plasmon Resonance Based Sensors
(2006) · Springer Series on Chemical Sensors and Biosensors · doi:10.1007/b100321 · Cited by 1,424
Zwitterionic SAMs that Resist Nonspecific Adsorption of Protein from Aqueous Buffer
Holmlin, R. E., Chen, X., Chapman, R. G., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la0015258 · Cited by 891
Ladd, J., Zhang, Z., Chen, S., Hower, J. C., & Jiang, S. (2008) · Biomacromolecules · doi:10.1021/bm701301s · Cited by 808
Self-citationMa, H., Hyun, J., Stiller, P., & Chilkoti, A. (2004) · Advanced Materials · doi:10.1002/adma.200305830 · Cited by 680
Lahiri, J., Isaacs, L., Tien, J., & Whitesides, G. M. (1999) · Analytical Chemistry · doi:10.1021/ac980959t · Cited by 601
Zhang, Z., Chen, S., & Jiang, S. (2006) · Biomacromolecules · doi:10.1021/bm060750m · Cited by 473
Self-citationOxidation of polyethylene glycols by alcohol dehydrogenase
Herold, D. A., Keil, K., & Bruns, D. E. (1989) · Biochemical Pharmacology · doi:10.1016/0006-2952(89)90151-2 · Cited by 400
Huang, N.-P., Vörös, J., De Paul, S. M., Textor, M., & Spencer, N. D. (2002) · Langmuir · doi:10.1021/la010913m · Cited by 268
Cited by
Jiang, S., & Cao, Z. (2010) · Advanced Materials · doi:10.1002/adma.200901407 · Cited by 2,027
Self-citationTargeted polymeric therapeutic nanoparticles: design, development and clinical translation
Kamaly, N., Xiao, Z., Valencia, P. M., Radovic-Moreno, A. F., & Farokhzad, O. C. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15344k · Cited by 1,730
Surface hydration: Principles and applications toward low-fouling/nonfouling biomaterials
Chen, S., Li, L., Zhao, C., & Zheng, J. (2010) · Polymer · doi:10.1016/j.polymer.2010.08.022 · Cited by 1,677
Nanoparticle Probes for the Detection of Cancer Biomarkers, Cells, and Tissues by Fluorescence
Chinen, A. B., Guan, C. M., Ferrer, J. R., Barnaby, S. N., Merkel, T. J., & Mirkin, C. A. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00321 · Cited by 1,032
Molecular Understanding and Design of Zwitterionic Materials
Shao, Q., & Jiang, S. (2015) · Advanced Materials · doi:10.1002/adma.201404059 · Cited by 908
Self-citationLi, Q., Wen, C., Yang, J., Zhou, X., Zhu, Y., Zheng, J., Cheng, G., Bai, J., Xu, T., Ji, J., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00344 · Cited by 790
Self-citationProtein Interactions with Polymer Coatings and Biomaterials
Wei, Q., Becherer, T., Angioletti‐Uberti, S., Dzubiella, J., Wischke, C., Neffe, A. T., Lendlein, A., Ballauff, M., & Haag, R. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201400546 · Cited by 743
Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics
Masson, J.-F. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00763 · Cited by 663
Krishnamoorthy, M., Hakobyan, S., Ramstedt, M., & Gautrot, J. E. (2014) · Chemical Reviews · doi:10.1021/cr500252u · Cited by 604
Interactions of nanomaterials and biological systems: Implications to personalized nanomedicine
Zhang, X.-Q., Xu, X., Bertrand, N., Pridgen, E., Swami, A., & Farokhzad, O. C. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.08.005 · Cited by 487
Anti-fouling Coatings of Poly(dimethylsiloxane) Devices for Biological and Biomedical Applications
Zhang, H., & Chiao, M. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0029-4 · Cited by 415
Protein–polyelectrolyte interactions
Kayitmazer, A. B., Seeman, D., Minsky, B. B., Dubin, P. L., & Xu, Y. (2013) · Soft Matter · doi:10.1039/c2sm27002a · Cited by 406
Synthesis, Assembly, and Applications of Hybrid Nanostructures for Biosensing
Zhang, S., Geryak, R., Geldmeier, J., Kim, S., & Tsukruk, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00088 · Cited by 340
Ultra-low fouling peptide surfaces derived from natural amino acids
Chen, S., Cao, Z., & Jiang, S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.001 · Cited by 335
Self-citationPiliarik, M., & Sandoghdar, V. (2014) · Nature Communications · doi:10.1038/ncomms5495 · Cited by 332
Self-citationCao, Z., & Jiang, S. (2012) · Nano Today · doi:10.1016/j.nantod.2012.08.001 · Cited by 329
Self-citationAnti-fouling bioactive surfaces
Yu, Q., Zhang, Y., Wang, H., Brash, J., & Chen, H. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.12.021 · Cited by 319
Pursuing “Zero” Protein Adsorption of Poly(carboxybetaine) from Undiluted Blood Serum and Plasma
Yang, W., Xue, H., Li, W., Zhang, J., & Jiang, S. (2009) · Langmuir · doi:10.1021/la9015788 · Cited by 305
Self-citationPhilip, A., & Kumar, A. R. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214424 · Cited by 281
Surface chemistry to minimize fouling from blood-based fluids
Blaszykowski, C., Sheikh, S., & Thompson, M. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35170f · Cited by 271
Polymer brushes: Applications in biomaterials and nanotechnology
Ayres, N. (2010) · Polym. Chem. · doi:10.1039/b9py00246d · Cited by 263
Xie, X., Doloff, J. C., Yesilyurt, V., Sadraei, A., McGarrigle, J. J., Omami, M., Veiseh, O., Farah, S., Isa, D., Ghani, S., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0273-3 · Cited by 235
Zhao, J., Shi, Q., Luan, S., Song, L., Yang, H., Shi, H., Jin, J., Li, X., Yin, J., & Stagnaro, P. (2011) · Journal of Membrane Science · doi:10.1016/j.memsci.2010.10.046 · Cited by 208
Zhao, C., Li, L., & Zheng, J. (2010) · Langmuir · doi:10.1021/la103382j · Cited by 100
Metadata
- Authors
- Vaisocherová, H., Yang, W., Zhang, Z., Cao, Z., Cheng, G., Piliarik, M., Homola, J., & Jiang, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-09-23
- Volume
- 80
- Issue
- 20
- Pages
- 7894-7901
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2078739630
- Cited by
- 409
- References
- 19
- FWCI
- 11.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.