Mass Cytometry: Technique for Real Time Single Cell Multitarget Immunoassay Based on Inductively Coupled Plasma Time-of-Flight Mass Spectrometry
Abstract
A novel instrument for real time analysis of individual biological cells or other microparticles is described. The instrument is based on inductively coupled plasma time-of-flight mass spectrometry and comprises a three-aperture plasma-vacuum interface, a dc quadrupole turning optics for decoupling ions from neutral components, an rf quadrupole ion guide discriminating against low-mass dominant plasma ions, a point-to-parallel focusing dc quadrupole doublet, an orthogonal acceleration reflectron analyzer, a discrete dynode fast ion detector, and an 8-bit 1 GHz digitizer. A high spectrum generation frequency of 76.8 kHz provides capability for collecting multiple spectra from each particle-induced transient ion cloud, typically of 200-300 micros duration. It is shown that the transients can be resolved and characterized individually at a peak frequency of 1100 particles per second. Design considerations and optimization data are presented. The figures of merit of the instrument are measured under standard inductively coupled plasma (ICP) operating conditions (<3% cerium oxide ratio). At mass resolution (full width at half-maximum) M/DeltaM > 900 for m/z = 159, the sensitivity with a standard sample introduction system of >1.4 x 10(8) ion counts per second per mg L(-1) of Tb and an abundance sensitivity of (6 x 10(-4))-(1.4 x 10(-3)) (trailing and leading masses, respectively) are shown. The mass range (m/z = 125-215) and abundance sensitivity are sufficient for elemental immunoassay with up to 60 distinct available elemental tags. When <15 elemental tags are used, a higher sensitivity mode at lower resolution (M/DeltaM > 500) can be used, which provides >2.4 x 10(8) cps per mg L(-1) of Tb, at (1.5 x 10(-3))-(5.0 x 10(-3)) abundance sensitivity. The real-time simultaneous detection of multiple isotopes from individual 1.8 microm polystyrene beads labeled with lanthanides is shown. A real time single cell 20 antigen expression assay of model cell lines and leukemia patient samples immuno-labeled with lanthanide-tagged antibodies is presented.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Mass spectrometry (MS) [161–164] and nuclear magnetic resonance (NMR) spectroscopy [165] are widely utilized technologies for metabolomics analysis.”
From Single-cell sequencing to multi-omics: technologies and applications (2024) · cites this paper as [164]
Citations
Cites
Semiconductor Nanocrystals as Fluorescent Biological Labels
Bruchez, M., Moronne, M., Gin, P., Weiss, S., & Alivisatos, A. P. (1998) · Science · doi:10.1126/science.281.5385.2013 · Cited by 8,613
Time-of-Flight Mass Spectrometer with Improved Resolution
Wiley, W. C., & McLaren, I. H. (1955) · Review of Scientific Instruments · doi:10.1063/1.1715212 · Cited by 3,678
Seventeen-colour flow cytometry: unravelling the immune system
Perfetto, S. P., Chattopadhyay, P. K., & Roederer, M. (2004) · Nature Reviews Immunology · doi:10.1038/nri1416 · Cited by 1,019
Spectral compensation for flow cytometry: Visualization artifacts, limitations, and caveats
Roederer, M. (2001) · Cytometry · doi:10.1002/1097-0320(20011101)45:3<194::aid-cyto1163>3.0.co;2-c · Cited by 558
Orthogonal acceleration time-of-flight mass spectrometry
Guilhaus, M., Selby, D., & Mlynski, V. (2000) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(2000)19:2<65::aid-mas1>3.0.co;2-e · Cited by 338
Polymer‐Based Elemental Tags for Sensitive Bioassays
Lou, X., Zhang, G., Herrera, I., Kinach, R., Ornatsky, O., Baranov, V., Nitz, M., & Winnik, M. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700796 · Cited by 282
Self-citationZhang, C., Zhang, Z., Yu, B., Shi, J., & Zhang, X. (2002) · Analytical Chemistry · doi:10.1021/ac0103468 · Cited by 246
A Sensitive and Quantitative Element-Tagged Immunoassay with ICPMS Detection
Baranov, V. I., Quinn, Z., Bandura, D. R., & Tanner, S. D. (2002) · Analytical Chemistry · doi:10.1021/ac0110350 · Cited by 194
Self-citation8 Color, 10-parameter flow cytometry to elucidate complex leukocyte heterogeneity
Roederer, M., Rosa, S. C. D., Gerstein, R. M., Anderson, M., Bigos, M., Stovel, R. T., Nozaki, T., Parks, D. R., Herzenberg, L. A., & Herzenberg, L. A. (1997) · Cytometry · doi:10.1002/(sici)1097-0320(19971201)29:4<328::aid-cyto10>3.0.co;2-w · Cited by 154
Multiple cellular antigen detection by ICP-MS
Ornatsky, O., Baranov, V. I., Bandura, D. R., Tanner, S. D., & Dick, J. E. (2005) · Journal of Immunological Methods · doi:10.1016/j.jim.2005.09.020 · Cited by 149
Self-citation
Research works printed but not linked: 7
- Baranov, V. I., Bandura, D. R. and Tanner, S. D.ICP-MS As an Elemental Detector in Immunoassays. Speciation without Chromatography. InEuropean Winter Conference on Plasma Spectrochemistry, Book of Abstracts, Lillehammer, Norway, February 4−8, 2001; p85.
- Zhang C., 2001, J. Anal. At. Spectrom., 16, 1393, 10.1039/b106387c · doi:10.1039/b106387c
- Hutchinson R. W., 2004, Can. J. Anal. Sci. Spectrosc., 49, 429
- Moore L., 1998, The Advantages of Time-of-Flight Mass Spectrometry for Elemental Analysis.
- Karataev V. I., 1971, J. Tech. Phys., 16, 1498
- Mamyrin B. A., 1973, Sov. Phys.-J. Exp. Theor. Phys., 37, 45
- Zavoisky E. K., 1956, Dokl. Akad. Nauk SSSR, 108, 218
Cited by
Mass-spectrometric exploration of proteome structure and function
Aebersold, R., & Mann, M. (2016) · Nature · doi:10.1038/nature19949 · Cited by 2,334
Bendall, S. C., Simonds, E. F., Qiu, P., Amir, E.-A. D., Krutzik, P. O., Finck, R., Bruggner, R. V., Melamed, R., Trejo, A., Ornatsky, O. I., et al. (2011) · Science · doi:10.1126/science.1198704 · Cited by 2,279
Self-citationHighly multiplexed imaging of tumor tissues with subcellular resolution by mass cytometry
Giesen, C., Wang, H. A. O., Schapiro, D., Zivanovic, N., Jacobs, A., Hattendorf, B., Schüffler, P. J., Grolimund, D., Buhmann, J. M., Brandt, S., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2869 · Cited by 1,951
Amir, E.-A. D., Davis, K. L., Tadmor, M. D., Simonds, E. F., Levine, J. H., Bendall, S. C., Shenfeld, D. K., Krishnaswamy, S., Nolan, G. P., & Pe'er, D. (2013) · Nature Biotechnology · doi:10.1038/nbt.2594 · Cited by 1,550
Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302
Metadata
- Authors
- Bandura, D. R., Baranov, V. I., Ornatsky, O. I., Antonov, A., Kinach, R., Lou, X., Pavlov, S., Vorobiev, S., Dick, J. E., & Tanner, S. D.
- Affiliations
- University Health Network (CA)
- Corresponding author
- Bandura, Dmitry R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-07-14
- Volume
- 81
- Issue
- 16
- Pages
- 6813-6822
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2038254572
- Cited by
- 1,295
- References
- 30
- Citations by year
- 2026: 49 · 2025: 67 · 2024: 95 · 2023: 100 · 2022: 105 · 2021: 137 · 2020: 115 · 2019: 114 · 2018: 106 · 2017: 91 · 2016: 68 · 2015: 58 · 2014: 47 · 2013: 49 · 2012: 35
- FWCI
- 13.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Genome Canada
- Ontario Genomics Institute
- Ruhr-Universität Bochum
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Spectroscopy › Laser-induced spectroscopy and plasma
- Keywords
- mass cytometry, single-cell analysis
- MeSH terms
- Antibodies, Antigens, Cell Separation, Immunoassay, Mass Spectrometry, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.