The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Label-Free Electrical Detection of Cardiac Biomarker with Complementary Metal-Oxide Semiconductor-Compatible Silicon Nanowire Sensor Arrays
Abstract
Arrays of highly ordered silicon nanowire (SiNW) clusters are fabricated using complementary metal-oxide semiconductor (CMOS) field effect transistor-compatible technology, and the ultrasensitive, label-free, electrical detection of cardiac biomarker in real time using the array sensor is presented. The successful detection of human cardiac troponin-T (cTnT) has been demonstrated in an assay buffer solution of concentration down to 1 fg/mL, as well as in an undiluted human serum environment of concentration as low as 30 fg/mL. The high specificity, selectivity, and swift response time of the SiNWs to the presence of ultralow concentrations of a target protein in a biological analyte solution, even in the presence of a high total protein concentration, paves the way for the development of a medical diagnostic system for point-of-care application that is able to provide an early and accurate indication of cardiac cellular necrosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
Cardiac troponin I. A marker with high specificity for cardiac injury.
Adams, J. E., Bodor, G. S., Dávila-Román, V. G., Delmez, J. A., Apple, F. S., Ladenson, J. H., & Jaffe, A. S. (1993) · Circulation · doi:10.1161/01.cir.88.1.101 · Cited by 1,148
Cardiac Troponin T Levels for Risk Stratification in Acute Myocardial Ischemia
Ohman, E. M., Armstrong, P. W., Christenson, R. H., Granger, C. B., Katus, H. A., Hamm, C. W., O’Hanesian, M. A., Wagner, G. S., Kleiman, N. S., Harrell, F. E., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351801 · Cited by 1,114
Electrical conduction through DNA molecules
Fink, H.-W., & Schönenberger, C. (1999) · Nature · doi:10.1038/18855 · Cited by 1,109
The Prognostic Value of Serum Troponin T in Unstable Angina
Hamm, C. W., Ravkilde, J., Gerhardt, W., Jørgensen, P., Peheim, E., Ljungdahl, L., Goldmann, B., & Katus, H. A. (1992) · New England Journal of Medicine · doi:10.1056/nejm199207163270302 · Cited by 953
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Cited by
Localized Surface Plasmon Resonance Sensors
Mayer, K. M., & Hafner, J. H. (2011) · Chemical Reviews · doi:10.1021/cr100313v · Cited by 4,350
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Chen, K.-I., Li, B.-R., & Chen, Y.-T. (2011) · Nano Today · doi:10.1016/j.nantod.2011.02.001 · Cited by 645
Zhang, A., & Lieber, C. M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00608 · Cited by 621
Metadata
- Authors
- Chua, J. H., Chee, R.-E., Agarwal, A., Wong, S. M., & Zhang, G.-J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-07-10
- Volume
- 81
- Issue
- 15
- Pages
- 6266-6271
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2031733876
- Cited by
- 266
- References
- 24
- FWCI
- 12.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Label-Free Electrical Detection of Cardiac Biomarker with Complementary Metal-Oxide Semiconductor-Compatible Silicon Nanowire Sensor Arrays. https://app.cochat.ai/papers/10.1021/ac901157x
- The paper
- Chua, J. H., Chee, R.-E., Agarwal, A., Wong, S. M., & Zhang, G.-J. (2009). Label-Free Electrical Detection of Cardiac Biomarker with Complementary Metal-Oxide Semiconductor-Compatible Silicon Nanowire Sensor Arrays. Analytical Chemistry. https://doi.org/10.1021/ac901157x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.