Technique for Real-Time Measurements of Endothelial Permeability in a Microfluidic Membrane Chip Using Laser-Induced Fluorescence Detection
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Characterizing permeability of the endothelium that lines blood vessels and heart valves provides fundamental physiological information and is required to evaluate uptake of drugs and other biomolecules. However, current techniques used to measure permeability, such as Transwell insert assays, do not account for the recognized effects of fluid flow-induced shear stress on endothelial permeability or are inherently low-throughput. Here we report a novel on-chip technique in a two-layer membrane-based microfluidic platform to measure real-time permeability of endothelial cell monolayers on porous membranes. Bovine serum albumin (a model protein) conjugated with fluorescein isothiocyanate was delivered to an upper microchannel by pressure-driven flow and was forced to permeate a poly(ethylene terephthalate) membrane into a lower microchannel, where it was detected by laser-induced fluorescence. The concentration of the permeate at the point of detection varied with channel flow rates in agreement to less than 1% with theoretical analyses using a pore flow model. On the basis of the model, a sequential flow rate stepping scheme was developed and applied to obtain the permeability of cell-free and cell-bound membrane layers. This technique is a highly sensitive, novel microfluidic approach for measuring endothelial permeability in vitro, and the use of micrometer-sized channels offers the potential for parallelization and increased throughput compared to conventional shear-based permeability measurement methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Self-citationOrganoid-on-a-chip and body-on-a-chip systems for drug screening and disease modeling
Skardal, A., Shupe, T., & Atala, A. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.07.003 · Cited by 512
“In one example, a device comprising two individual channels passing perpendicular to one another was developed [36].”
MethodOrgan-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
Tubeless microfluidic angiogenesis assay with three-dimensional endothelial-lined microvessels
Bischel, L. L., Young, E. W. K., Mader, B. R., & Beebe, D. J. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.11.005 · Cited by 265
Self-citationCardiovascular organ-on-a-chip platforms for drug discovery and development
Ribas, J., Sadeghi, H., Manbachi, A., Leijten, J., Brinegar, K., Zhang, Y. S., Ferreira, L., & Khademhosseini, A. (2016) · Applied In Vitro Toxicology · doi:10.1089/aivt.2016.0002 · Cited by 161
“Young et al.127 developed a microfluidic system and technique to measure real-time endothelial permeability by using laser-induced fluorescence.”
Method
Metadata
- Authors
- Young, E. W. K., Watson, M. W. L., Srigunapalan, S., Wheeler, A. R., & Simmons, C. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-01-05
- Volume
- 82
- Issue
- 3
- Pages
- 808-816
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2081456070
- Cited by
- 102
- References
- 1
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Technique for Real-Time Measurements of Endothelial Permeability in a Microfluidic Membrane Chip Using Laser-Induced Fluorescence Detection. https://app.cochat.ai/papers/10.1021/ac901560w
- The paper
- Young, E. W. K., Watson, M. W. L., Srigunapalan, S., Wheeler, A. R., & Simmons, C. A. (2010). Technique for Real-Time Measurements of Endothelial Permeability in a Microfluidic Membrane Chip Using Laser-Induced Fluorescence Detection. Analytical Chemistry. https://doi.org/10.1021/ac901560w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.