Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.

Theory of Midinfrared Absorption Microspectroscopy: I. Homogeneous Samples

Davis, Brynmor J., Carney, P. Scott, Bhargava, Rohit · 2010 · Analytical Chemistry

Abstract

Midinfrared (IR) microspectroscopy is widely employed for spatially localized spectral analyses. A comprehensive theoretical model for the technique, however, has not been previously proposed. In this paper, rigorous theory is presented for IR absorption microspectroscopy by using Maxwell's equations to model beam propagation. Focusing effects, material dispersion, and the geometry of the sample are accounted to predict spectral response for homogeneous samples. Predictions are validated experimentally using Fourier transform IR (FT-IR) microspectroscopic examination of a photoresist. The results emphasize that meaningful interpretation of IR microspectroscopic data must involve an understanding of the coupled optical effects associated with the sample, substrate properties, and microscopy configuration. Simulations provide guidance for developing experimental methods and future instrument design by quantifying distortions in the recorded data. Distortions are especially severe for transflection mode and for samples mounted on certain substrates. Last, the model generalizes to rigorously consider the effects of focusing. While spectral analyses range from examining gross spectral features to assessing subtle features using advanced chemometrics, the limitations imposed by these effects in the data acquisition on the information available are less clear. The distorting effects are shown to be larger than noise levels seen in modern spectrometers. Hence, the model provides a framework to quantify spectral distortions that may limit the accuracy of information or present confounding effects in microspectroscopy.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac902067p

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 55 references

Research works printed but not linked: 2

  1. Born M., 1980, Principles of Optics
  2. Griffiths, P. R. and de Haseth, J. A.InFourier Transform Infrared Spectrometry,2nd ed.Wiley-Interscience:Hoboken, NJ, 2007; Chapter 11.1.3, pp253−255.

Cited by

See all 115

Metadata

Authors
Davis, B. J., Carney, P. S., & Bhargava, R.
Affiliations
University of Illinois Urbana-Champaign (US)
Corresponding author
Bhargava, Rohit
Venue
Analytical Chemistry
Published
2010-04-14
Volume
82
Issue
9
Pages
3474-3486
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1980515691
Cited by
115
References
55
Citations by year
2026: 1 · 2025: 4 · 2023: 2 · 2022: 7 · 2021: 4 · 2020: 9 · 2019: 6 · 2018: 6 · 2017: 10 · 2016: 5 · 2015: 9 · 2014: 10 · 2013: 11 · 2012: 15
FWCI
7.94
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • U.S. Department of Defense
  • Grainger Foundation
  • Susan G. Komen
  • DOD Prostate Cancer Research Program
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Near-Field Optical Microscopy
Keywords
Maxwell's equations, focusing effect, material dispersion, spectral distortion, homogeneous samples, photoresist, substrate effects, chemometrics
MeSH terms
Models, Theoretical, Spectrophotometry, Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.