The DOI matches its Crossref record.
Amperometric Detection of Dopamine in Vivo with an Enzyme Based Carbon Fiber Microbiosensor
Abstract
We developed a novel implantable enzyme-based carbon fiber biosensor for in vivo monitoring of dopamine. The biosensor is fabricated using tyrosinase immobilized in a biocompatible matrix consisting of a biopolymer, chitosan and ceria-based metal oxides, deposited onto the surface of a carbon fiber microelectrode with a diameter of approximately 100 microm. Tyrosinase catalyzes the conversion of dopamine to o-dopaquinone, and the reduction of o-dopaquinone, which requires a low potential difference, was detected electrochemically. The role of each component in the sensing layer was systematically investigated in relation to the analytical performance of the biosensor. In its optimal configuration, the biosensor demonstrated a detection limit of 1 nM dopamine, a linear range of 5 orders of magnitude between 10 nM and 220 microM, a sensitivity of 14.2 nA x microM(-1), and good selectivity against ascorbic acid, uric acid, serotonin, norepinephrine, epinephrine, and 3,4-dihydroxy-l-phenylalanine (L-DOPA). The system provided continuous, real time monitoring of electrically stimulated dopamine release in the brain of an anesthetized rat. Levels of dopamine up to 1.69 microM were measured. This new implantable dopamine biosensor provides an alternative to fast scan cyclic voltammetry for in vivo monitoring of dopamine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Recent trends in carbon nanomaterial-based electrochemical sensors for biomolecules: A review
Yang, C., Denno, M. E., Pyakurel, P., & Venton, B. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.05.049 · Cited by 577
Rocchitta, G., Spanu, A., Babudieri, S., Latte, G., Madeddu, G., Galleri, G., Nuvoli, S., Bagella, P., Demartis, M., Fiore, V., et al. (2016) · Sensors · doi:10.3390/s16060780 · Cited by 555
Electrochemical Biosensor Applications of Polysaccharides Chitin and Chitosan
Suginta, W., Khunkaewla, P., & Schulte, A. (2013) · Chemical Reviews · doi:10.1021/cr300325r · Cited by 521
New trends in the electrochemical sensing of dopamine
Jackowska, K., & Krysinski, P. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6578-2 · Cited by 461
Farmer, A. D., Strzelczyk, A., Finisguerra, A., Gourine, A. V., Gharabaghi, A., Hasan, A., Burger, A. M., Jaramillo, A. M., Mertens, A., Majid, A., et al. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.568051 · Cited by 355
Nanotechnology-based approaches for food sensing and packaging applications
Mustafa, F., & Andreescu, S. (2020) · RSC Advances · doi:10.1039/d0ra01084g · Cited by 332
Self-citationBiosensors and sensors for dopamine detection
Liu, X., & Liu, J. (2021) · VIEW · doi:10.1002/viw.20200102 · Cited by 329
Employing Conductive Metal–Organic Frameworks for Voltammetric Detection of Neurochemicals
Ko, M., Mendecki, L., Eagleton, A. M., Durbin, C. G., Stolz, R. M., Meng, Z., & Mirica, K. A. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.9b13402 · Cited by 298
Miller, G. M. (2011) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2010.07109.x · Cited by 249
Dopamine biosensor based on surface functionalized nanostructured nickel oxide platform
Roychoudhury, A., Basu, S., & Jha, S. K. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.061 · Cited by 184
Metadata
- Authors
- Njagi, J., Chernov, M. M., Leiter, J. C., & Andreescu, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-01-07
- Volume
- 82
- Issue
- 3
- Pages
- 989-996
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2072159678
- Cited by
- 264
- References
- 0
- FWCI
- 15.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.